Frame: Trunk Monitoring (Real-Time); 2.15.1 Tab: Trunk Performance - AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual

Table of Contents

Advertisement

2.15

Frame: Trunk Monitoring (Real-Time)

2.15.1 Tab: Trunk Performance

Frame: Trunk Monitoring (Real-Time), Tab: Trunk Performance
EMS Parameter Name RT / Hist Gauge /
Trunk utilization
Trunk Calls Duration
Trunk Errored Seconds
Trunk Controlled Slip
Seconds
Trunk Path Coding
Violations
Trunk Bursty Errored
Seconds
Performance Monitoring and Alarms
Counter
RT
Gauge
This attribute indicates the Current simultaneous busy
DS0 channels on this Trunk. A busy channel is when
the Physical DS0 Termination isn't in Null context or
OOS. A Trunk is either E1 or T1.
Mib name: acPMTrunkUtilizationVal
RT
Gauge
Value of gauge or counter.
Mib name: acPMPSTNTrunkActivitySecondsVal
RT
Gauge
This attribute indicates amount of Errored Seconds
encountered by a DS1 interface in the previous 24 hour
interval. Invalid 15 minute intervals count as 0.
Mib name: dsx1TotalESs
RT
Gauge
This attribute indicates amount of Controlled Slip
Seconds encountered by a DS1 interface in the
previous 24 hour interval. Invalid 15 minute intervals
count as 0.
Mib name: dsx1TotalCSSs
RT
Gauge
This attribute indicates amount of Path Coding
Violations encountered by a DS1 interface in the
previous 24 hour interval. Invalid 15 minute intervals
count as 0.
Mib name: dsx1TotalPCVs
RT
Gauge
This attribute indicates amount of Bursty Errored
Seconds encountered by a DS1 interface in the
previous 24 hour interval. Invalid 15 minute intervals
count as 0.
Mib name: dsx1TotalBESs