Ha System Fault Alarm - AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual

Table of Contents

Advertisement

Performance Monitoring and Alarms
3.4.22

HA System Fault Alarm

Description
SNMP Alarm
SNMP OID
Alarm Title
Alarm Source
AlarmType
Probable Cause
Alarm Severity
Critical (default)
Version 7.0
HA System Fault Alarm
This alarm originates when:
HA feature is active but the system is NOT working in HA mode.
Reason is specified (for example: SW WD exception error, HW WD
exception error, SAT device is missing, SAT device error, DSP error,
BIT tests error, etc).
HA feature is active and the redundant module is in start up mode but
hasn't connected yet
HA system is active
acHASystemFaultAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.33
HA System Fault Alarm
System#0/Module#<m>, where m is the blade module's slot number
qualityOfServiceAlarm
outOfService
Condition
HA feature is
Fatal exception error
active but the
system is not
working in HA
mode
TCPIP exception error
Network processor
exception error
(applicable only to
Mediant 3000)
SW WD exception error HA was lost due to switchover
HW WD exception
error
<text>
High Availability (HA) was lost
due to switchover and should
return automatically after a few
minutes. Corrective action is not
required.
HA was lost due to switchover
and should return automatically
after a few minutes.
Corrective action is not
required.
HA was lost due to switchover
and should return automatically
after a few minutes.
Corrective action is not
required.
and should return automatically
after a few minutes.
Corrective action is not
required.
HA was lost due to switchover
and should return automatically
after a few minutes.
Corrective action is not
required.
113
Performance Monitoring and Alarms
3. Alarms
Corrective Action