Nfas Group Alarm - AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual

Table of Contents

Advertisement

3.4.58

NFAS Group Alarm

Description
SNMP Alarm
SNMP OID
Alarm Source
Alarm Type
Probable Cause
Alarm Severity
Major (default)
Clear
Performance Monitoring and Alarms
NFAS Group Alarm
This alarm is raised when an NFAS group goes Out-Of-Service and is
cleared when an NFAS Group is back In-Service.
acNFASGroupAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.84
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1
being the first trunk
communicationsAlarm
degradedSignal
Condition
Raised when an NFAS
group goes out-of-
service
NFAS group state
goes to in- service
146
Mediant 3000 with TP-6310
<text>
NFAS Group
Alarm. %s
%s– Additional
-
information
Document #: LTRT-32111
Corrective Action
The alarm is sent only
when the backup Non-
Facility Associated
Signaling (NFAS) D-
channel also falls, i.e.,
when both D-channels
are down.
When at least one of
the
D-channels (primary or
backup) returns to
service, the alarm is
cleared.
Corrective action is not
necessary.