Trunk Los Alarm - AudioCodes Mediant 3000 TP-6310 Performance Monitoring And Alarm Manual

Table of Contents

Advertisement

Performance Monitoring and Alarms
3.4.34

Trunk LOS Alarm

This alarm applies to E1/T1Trunks.
Description
SNMP Alarm
SNMP OID
Alarm Title
Alarm Source
Alarm Type
Probable Cause
Alarm Severity
Critical (default)
Cleared
Version 7.0
Trunk LOS Alarm
This alarm indicates a loss of signal at the trunk's near end.
acTrunksAlarmNearEndLOS
1.3.6.1.4.1.5003.9.10.1.21.2.0.49
Trunk LOS Alarm
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1
being the first trunk
communicationsAlarm
lossOfSignal
Condition
<text>
Near-end
Trunk LOS
LOS
Alarm
End of LOS
-
127
Corrective Action
Los of Signal (LOS) indicates a physical
problem.
1.
Check that the cable is connected on
the board.
2.
Check that the correct cable type is
being used (crossed/straight).
3.
Contact AudioCodes' Support Center
at
support@audiocodes.com.
-