Performance Monitoring and Alarms
Minor
Version 7.0
HW fault. TER has old
version or is not
functional
(applicable only to
Mediant 3000)
HW fault. invalid TER
Type
(applicable only to
Mediant 3000)
HW fault. invalid TER
active/redundant state
(applicable only to
Mediant 3000)
HW fault. Error reading
GbE state
(applicable only to
Mediant 3000)
Redundant module is
missing
(applicable only to
Mediant 3000)
Redundant is not
connecting
(applicable only to
Mediant 3000)
Redundant is not
reconnecting after
deliberate restart
No Ethernet Link in
redundant module
SA module faulty or
missing
(applicable only to
Mediant 3000)
Eth link error
Higher HA priority
(Not applicable to
Mediant 3000)
Network watchdog
error
HA feature is
Waiting for redundant
to connect
active and the
redundant
(applicable only to
module is in
Mediant 3000)
startup mode
and hasn't
connected yet
Replace the TER card.
Replace the TER card.
Replace the TER card.
Replace the TER card.
1.
2.
Reset / replace the redundant
module.
Reset / replace the redundant
module.
Connect Ethernet links to the
redundant module
Make sure the Shelf Alarm
module is inserted correctly.
HA was lost due to switchover,
Connect the Eth link back.
HA was lost due to switchover
to unit with higher HA priority
and should return automatically
after a few minutes.
Corrective action is not
required.
HA was lost due to switchover ,
Fix the network connectivity
from failed unit
Corrective action is not
required.
115
Performance Monitoring and Alarms
3. Alarms
Insert the redundant module
into the system.
If the error continues, reset /
replace the module.

Advertisement