Additional Info
Corrective Action
3.2.20
EMS Keep Alive Alarm
Description
SNMP Alarm
SNMP OID
Default Severity
Alarm Type
Probable Cause
Alarm Text
Status Changes
Additional Info
Corrective Action
3.2.21
Pre-provisioning Alarm
Description
SNMP OID
AlarmTitle
AlarmType
AlarmSource
Probable Cause
Severity
Additional Info
Performance Monitoring and Alarms
Investigate the recurrence of such alarms.
This alarm indicates that an SNMP Keep-alive trap has been sent
from EMS to a third-party destination such as a Syslog server to
indicate EMS liveness (configured in the EMS Alarms Settings
window).
EMSKeepAliveAlarm
1.3.6.1.4.1.5003.9.20.3.2.0.45
Indeterminate
Other
Other
EMS Server Keep-Alive
This alarm is generated when the operation for pre-provisioning the
device upon initial connection to the EMS fails.
1.3.6.1.4.1.5003.9.20.3.2.0.46
Pre-Provisioning
operational/Violation
EMS server
The template file could not be applied to the device because there was
a mismatch between the template file and the device's existing ini file
or there was a mismatch between the device type and the firmware file
applied to the device.
Critical
-
90
Mediant 3000 with TP-6310
Document #: LTRT-32111