Oil Rubbed Bronze CF130WW00 - Appliance White 10.6 Net Weight: Lbs. Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-800-654-3545 Part No. F40BP74040001 Form No. BP7404-1 www.emersonfans.com Revision: 130607...
Emerson Electric Co. Substitution of parts or accessories not Additional Safety Instructions for Installation designated for use with this product by Emerson could result in personal injury or property damage. 1. To avoid possible shock, be sure electricity is turned...
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product Hanger Ball/4.5” Downrod Assembly by Emerson Electric Co. could result in personal injury or property damage. SW46 Wall Control 1. Check to see that you have received the following...
THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS... ANYWHERE THERE IS A ROOF OVERHEAD. USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN DAMP LOCATIONS. This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G.
Ceiling Fan Assembly 1. Position the fan motor assembly upside down in M5 x 14mm FLANGE HEAD BLADE preparation for mounting the three fan blades. SCREWS (2 per blade) 2. Rotate the notched switch assembly to expose the HOUSING holes for blade assembly (Figure 1). NOTCHED SWITCH ASSEMBLY 3.
Page 6
Ceiling Fan Assembly (continued) Installing the Hanger Ball/ Downrod Assembly for Standard Mounting 1. Carefully turn the partially assembled ceiling fan right HANGER BALL side up and place the fan securely into the packing sytrofoam in preparation for final assembly. 2.
Page 7
Ceiling Fan Assembly (continued) 6. Place the decorative lower cover and ceiling cover over the downrod. Be sure both pieces are oriented correctly (Figure 7). 7. Reinstall the hanger ball (Figure 8) on the downrod as follows. Route the motor leads through the downrod.
3. Position the ceiling cover onto the top of the motor COVER housing and reattach the three screws previously removed (Figure 10). Please call Emerson technical support SCREW (3) 1-800-654-3545 if you have any questions about installation and operation of this ceiling fan.
Page 9
How to Hang Your Ceiling Fan (continued) WARNING LOOSEN TWO Turning off wall switch is not sufficient. To avoid SCREWS (SUPPLIED possible electrical shock, be sure electricity is turned WITH OUTLET BOX) OUTLET off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
Page 10
How to Hang Your Ceiling Fan (continued) How to Hang Your Ceiling Fan For Standard Mounting 1. Carefully lift the fan assembly and seat the hanger ball in the hanger bracket (Figure 15). The tab on the hanger bracket must seat in the groove in the hanger ball.
NOTE: If you are using an Emerson Light Fixture connectors, except for the ground wire. Do not with your fan, see Light Fixture Owner’s Manual for operate fan until blades are in place.
Installation of Ceiling Cover Installation of Ceiling Cover For INSTALL SCREW AND LOCKWASHER Close-to-the-Ceiling TIGHTEN CEILING SCREW COVER NOTE: When installing the ceiling fan using the close-to-the-ceiling method, carefully lift the fan assembly from the hook on the hanger bracket and proceed as follows.
Using Your Ceiling Fan IMPORTANT Fan installation must be completed, including the installation of the fan blades, before testing of the controls. 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2.
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product The use of any other control not specifically approved by Emerson Electric Co. could result in personal injury for this fan could result in fire, shock and personal or property damage.
Trouble Shooting WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
Page 19
What We Will Do To Correct Problems: If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during the expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or workmanship, you must contact Emerson during the applicable warranty period.
Page 20
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-800-654-3545 www.emersonfans.com Retain this manual for future use.