6 Applications

6.1 Application defaults

The default values for each selected application are shown by in the table below.
Code
Parameter
P3.2.1
Remote operating location
P3.2.2
Local/Distance
P3.2.6
Logic I/O A
P3.2.7
Logic I/OB
P3.3.1.5
Reference Selection I/O A
P3.3.1.6
Selection I/O reference B
P3.3.6.2
Flushing reference
P3.5.1.1
Control signal 1 A
P3.5.1.2
Control signal 2 A
P3.5.1.4
Control signal 1 A
P3.5.1.7
Force control to I/O B
P3.5.1.8
Force I/O B-reference
P3.5.1.11
Close external error
P3.5.1.13
Close error reset
P3.5.1.21
Fixed frequency selection 0
P3.5.1.22
Fixed frequency selection 1
P3.5.1.31
PID SP selection
P3.5.1.36
Activation flushing reference
P3.5.1.42
Pump 1 block
P3.5.1.43
Pump 2 block
P3.5.1.44
Pump 3 block
P3.5.3.2.1
RO1 function
P3.5.3.2.4
RO2 function
P3.5.3.2.7
RO3 function
Reference point source 1
P3.13.2.6
select
Reference point source 2
P3.13.2.10
select
P3.13.3.1
PID feedback function
P3.13.3.3
PID feedback source
P3.15.1
Multi-pump, mode
P3.15.2
Number of pumps
P3.15.5
Pump block
P3.15.6
Autochange
P3.15.7
Autochange pumps
P3.15.8
Autochange interval
P3.15.11
Autochange frequency limit
P3.15.12
Autochange pump limit
P3.15.13
Range
P3.15.14
Range delay
P3.15.15
Constant production speed

6.2 Start Application via Wizard

Default setting
0
0
0
0
0
0
0
0
2
2
2
2
2
2
2
2
6
6
7
7
4
4
4
4
0 Hz
0 Hz
0 Hz
0 Hz
A.1
A.1
A.1
A.1
A.2
A.2
0.1
0.1
0.1
0.1
A.4
A.2
0.1
0.1
A.6
A.3
0.1
0.1
A.6
A.3
A.3
A.3
A.2
0.1
A.6
A.6
A.3
0.1
A.4
A.4
A.5
0.1
A.5
A.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
A.4
0.1
0.1
0.1
A.5
0.1
0.1
0.1
A.6
2
2
2
49
3
3
3
50
1
1
1
51
-
-
3
3
-
-
-
-
-
-
1
1
-
-
2
2
-
-
-
0
1
1
1
3
-
-
-
1
-
-
-
1
-
-
-
1
-
-
-
48 h
-
-
-
25 Hz
-
-
-
1
-
-
-
10%
-
-
-
10 s
-
-
-
-
ID
Description
0
172
0 = Control I/O
0
211
0 = Remote
2
300
2 = Forward-Reverse (Pulse)
2
363
2 = Forward-Reverse (Pulse)
6 = AI 1 + AI 2
7
117
7 = PID
4
131
4 = AI 1
50 Hz
1239
A.1
403
0.1
404
0.1
423
0.1
425
0.1
343
A.6
405
A.4
414
0.1
419
0.1
420
A.3
1047
A.2
530
0.1
426
0.1
427
0.1
428
2 = In operation
2
11001
49 = Multi-pump K1 control
3 = Error
3
11004
50 = Multi-pump K2 control
1 = Ready
1
11007
51 = Multi-pump K3 control
3
332
3 = AI 1
1
431
1 = Control panel ref. point 1
1
333
1 = Only source 1 in use
2
334
2 = AI 2
0 = Single drive
2
1785
2 = Multi-master
3
1001
1
1032
1 = Unblocked
1
1027
1 = enabled
1
1028
1 = All pumps
48 h
1029
50 Hz
1031
3
1030
10%
1097
10 s
1098
100%
1513
Vacon 100 Flow
24
page