Advertisement

Quick Links

Installation manual
Enpres
High pressure pumps
Series XX/XX E & B
Versie 3.0
5 november 2021
IMPROVING YOUR BUSINESS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for VAN DER ENDE E Series

  • Page 1 Installation manual Enpres High pressure pumps Series XX/XX E & B Versie 3.0 5 november 2021 IMPROVING YOUR BUSINESS...
  • Page 2 When there’s a number between brackets behind a component this refers to the component number in image 3, 4 or 5. Montagehandleiding Enpres Page 2 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 3: Table Of Contents

    Reparation/revision kits pump/pressure regulator ...............27 Exploded-view pump .........................28 Exploded-view pressure regulator ....................30 Montagehandleiding Enpres Page 3 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 4: Identification

    Petrol engine +/- 70 Table 2. Weight of the entire Enpres Montagehandleiding Enpres Page 4 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 5: Schematic Representation Of The Machine

    However, the principle will remain the same. Montagehandleiding Enpres Page 5 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 6: Intended Users

    The Enpres is not intended for use other than described above. Montagehandleiding Enpres Page 6 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 7: Media

    According to the low voltage directive the Enpres has been classified as a class I machinery. Montagehandleiding Enpres Page 7 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 8: Remaining Risks

    When the installation is not connected correctly there will be danger for users. Table 5. List of rest risk Montagehandleiding Enpres Page 8 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 9: Description

    The Enpres must be protected from water and dirt and is IP54. Montagehandleiding Enpres Page 9 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 10: Parts

    Adjustment screw for adjusting alignment motor and pump Table 6. Enpres parts, description 1 Montagehandleiding Enpres Page 10 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 11 Press connection Electronic pressure switch (optional) Table 7. Enpres parts, description 2 Montagehandleiding Enpres Page 11 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 12 Type plate pump Oil drain plug Table 8. Enpres parts, description 3 Montagehandleiding Enpres Page 12 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 13: Safety Instructions

    Follow all installation and safety instructions. Ignoring these instruction van cause serious injury or damage to people and products. Montagehandleiding Enpres Page 13 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 14: Installation

    Maximum over- and underpressure of lines and fittings must not be exceeded. Montagehandleiding Enpres Page 14 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 15: Installation

     place a emergency stop where needed. Montagehandleiding Enpres Page 15 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 16: Actions Before Use

    (20);  the pump is now ready for use. Montagehandleiding Enpres Page 16 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 17: Using The Enpres

    (21)! Montagehandleiding Enpres Page 17 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 18: Stopping

    When the pump is left empty for a long period of time problems can occur with sticking non return valves, see chapter 7 or contact the manufacturer. Montagehandleiding Enpres Page 18 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 19: Maintenance

    Enpres leaks oil; contact the manufacturer; Montagehandleiding Enpres Page 19 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 20: Tensioning V-Belts

    Leakage of oil can result in the pump running dry on oil and overheating the internal transmissions. Contact the manufacturer in order to prevent irreparable damage. Montagehandleiding Enpres Page 20 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 21: Errors

    Errors with the petrol engine must be solved with the instruction manual of the petrol engine itself. Montagehandleiding Enpres Page 21 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 22: Declaration Of Conformity

    Directives. The Netherlands P.J. van der Ende Maasdijk 5 November 2009 Montagehandleiding Enpres Page 22 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 23: Annexes

    Reparation/revision kits.  Exploded view pump.  Exploded view pressure regulator. Montagehandleiding Enpres Page 23 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 24: Electrical Connection Of The Three Position Switch

    32 in order to change the direction of rotation. Montagehandleiding Enpres Page 24 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 25: Electrical Connection Direct On The Electro Motor

    Look at the type plate of the electro motor for more information. Montagehandleiding Enpres Page 25 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 26: Electrical Connection Pressure Switch

    The pressure switch is set to a pressure of 15 bar, this can easily be checked with the blue swivel. Montagehandleiding Enpres Page 26 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 27: Reparation/Revision Kits Pump/Pressure Regulator

    Reparation/revision kits pump/pressure regulator The kits beneath are kits for the reparation of revision of pump or pressure regulator. Ordering these kits or other parts can be done by contacting the manufacturer, Van der Ende Pompen B.V. Kit name Suited for Parts in kit Articlenr.
  • Page 28: Exploded-View Pump

    Exploded-view pump Exploded-view pump T33/44/55 Montagehandleiding Enpres Page 28 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 29 Exploded-view pump T77/88 Montagehandleiding Enpres Page 29 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...
  • Page 30: Exploded-View Pressure Regulator

    Exploded-view pressure regulator Exploded-view pressure regalator Montagehandleiding Enpres Page 30 of 30 Van der Ende Groep · Aartsdijkweg 23, 2676 LE Maasdijk, the Netherlands +31 174 515 050 · info@vanderendegroep.nl · www.vanderendegroep.com IMPROVING YOUR BUSINESS...

Table of Contents