36
Media SSD Storage
drive letter in turn (E:, F:, G:, etc.) before inserting the next. You will need to be able to identify them in the
next test.
Now go to 'C:\7thSense\Software & Drivers\Software\Test Utilities\AS SSD Benchmark' and open the 'AS SSD'
application.
Select the first SSD disk, E: (ignore C: drive)
Check the 'Seq' test only, then Start.
Note down the read and write speed for each of the SSDs.
Identify and remove the faulty SSD
If one SSD is markedly different from the rest, you can identify and replace this disk.
If there is no obvious result, then the SSD problem may only appear when SSD is part of RAID0 set.
Identification is now a process of elimination.
Create 2 individual (e.g. 4 out of 8) disk Movie Drives, and name them [e.g. Movie Drive 1 (E), Movie Drive 2
(F)], then do the speed test again with AS SSD.
Hardware Operation
© 2020 7thSense Design
Need help?
Do you have a question about the Delta Media Server and is the answer not in the manual?
Questions and answers