I/O Integration
Automation Inputs (EFR Outputs)
Automation Outputs (EFR Inputs)
Trigger Signal (Foot Switch)
Sequence Select Bits (optional command)
Sequence Running
Key
EFR Sequence is running
If the sequence is not in operator mode, a pulse on the trigger pin will result in the sequence being played.
Sending the sequence select bits is optional. If the sequence select bits are not sent, the EFR will use the current
selected sequence.
Automation Inputs (EFR Outputs)
Automation Outputs (EFR Inputs)
Trigger Signal (Foot Switch)
Sequence Select Bits (optional command)
Sequence Running
Key
EFR Sequence is running in Operator Mode
Analog Flow Rate Set Point Command can be
used to modify flow rate on the fly
If a shot is in operator mode throughout a sequence, the EFR will only dispense that shot if the trigger pin is ON.
Once the trigger pin is OFF, the EFR will continue to the next shot in the sequence.
62
System Ready
Alarm Active
Valve Signal
System Enable
EFR State
System Ready
Alarm Active
Valve Signal
System Enable
EFR State
EFR Discrete Signal Run Sequence
EFR Discrete Signal Run Sequence in Operator Mode
3A6165J