Graco EFR Instructions-Parts List Manual page 28

Electric fixed-ratio proportioner
Hide thumbs Also See for EFR:
Table of Contents

Advertisement

Troubleshooting
Error Code
Code Description
CACV
Comm. Error Voltex
Dynamic Mix Valve
Module
CCCC
Comm. Error
Gateway
DDDA
Pump Cavitation A
DDDB
Pump Cavitation B
DHDA
Leak Detected
Outlet A
DHDB
Leak Detected
Outlet B
F3NX
Unable to Maintain
Flow Rate
28
Cause
No 24 VDC power supply to ADM
Cross threaded CAN cable
Automation gateway lost
communication with automation
controller
Out of material
Check valve not working properly
Out of material
Check valve not working properly
Pressure leaking from A side while
stalled at pressure
Pressure leaking from B side while
stalled at pressure
Pump is unable to deliver the
desired flow rate
Solution
Reconnect or replace CAN cable
connecting FCM and ADM. If CAN
connection good, check 24V power
supply wiring inside the controller
enclosure. Make sure AC power to
control enclosure is turned off before
checking power supply. Yellow LED
on FCM should be flashing.
CAN cables carry 24 V DC power
and communication between
modules. A cross threaded CAN
cable connector may cause
problems with communication
and/or power to modules. Carefully
check for cross threaded CAN
connections on the ADM and FCM.
Yellow LED on FCM board should
be flashing.
Verify fieldbus cable is properly
connected.
Verify host is communicating.
Verify A material supply
Inspect and clean A side check
valve. Check for leaking seals or
damage to the ball
Verify B material supply
Inspect and clean B side check
valve. Check for leaking seals or
damage to the ball
Visually inspect the machine and
hoses for signs of material leakage.
Inspect seals in pump and ball
check.
Visually inspect the machine and
hoses for signs of material leakage.
Inspect seals in pump and ball
check.
Reduce flow rate
Increase pump sizes
Measure line voltage. Low line
voltage may reduce maximum
operating flow rate.
3A6165J

Advertisement

Table of Contents
loading

Table of Contents