Graco EFR Instructions-Parts List Manual page 34

Electric fixed-ratio proportioner
Hide thumbs Also See for EFR:
Table of Contents

Advertisement

Troubleshooting
Error Code
Code Description
P4FB
High Pressure
Alarm Inlet B
P6DA
Pressure Sensor
Error Outlet A
P6DB
Pressure Sensor
Error Outlet B
P6FA
Pressure Sensor
Error Inlet A
P6FB
Pressure Sensor
Error Inlet B
P7DA
Pressure Imbalance
High A
34
Cause
Pressure B exceeds user-defined
dispense pressure limit.
Loose or bad sensor connection to
Motor Control Module
Faulty sensor
Loose or bad sensor connection to
Motor Control Module
Faulty sensor
Loose or bad sensor connection to
Motor Control Module
Faulty sensor
Loose or bad sensor connection to
Motor Control Module
Faulty sensor
Dispense line is clogged
Orifice restrictions sized incorrectly
Out of material
Pressure imbalance is defined too
low
Solution
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
Check to make sure that the
pressure sensor is properly
connected to connector 6 of the
Motor Control Module (MCM)
Replace the Pressure Sensor
Check to make sure that the
pressure sensor is properly
connected to connector 5 of the
Motor Control Module (MCM)
Replace the Pressure Sensor
Check to make sure that the
pressure sensor is properly
connected to the connector 6 of the
Fluid Control Module (FCM).
Replace the Pressure Sensor
Check to make sure that the
pressure sensor is properly
connected to connector 5 of the
Fluid Control Module (FCM).
Replace the Pressure Sensor
First try purging fresh material
through the system. Then relieve
pressure and check for cured
material or obstructions in the
dispense valve.
Adjust orifice restrictions to balance
pressure of A and B materials
Verify B material supply
Increase pressure imbalance
amount from the Setup screen of the
Advanced Display Module (ADM)
3A6165J