Graco EFR Instructions-Parts List Manual page 31

Electric fixed-ratio proportioner
Hide thumbs Also See for EFR:
Table of Contents

Advertisement

Error Code
Code Description
P2DA
Low Pressure
Deviation Outlet A
P2DB
Low Pressure
Deviation Outlet B
P2FA
Low Pressure
Deviation Inlet A
P2FB
Low Pressure
Deviation Inlet B
P3FA
High Pressure
Deviation Inlet A
P3FB
High Pressure
Deviation Inlet B
P3FC
High Pressure
Deviation Inlet A
P3FD
High Pressure
Deviation Inlet B
3A6165J
Cause
Pressure A is below user-defined
dispense pressure limit
Pressure B is below user-defined
dispense pressure limit
Pressure A is below user-defined
dispense pressure limit
Pressure B is below user-defined
dispense pressure limit
Pressure A exceeds user-defined
dispense pressure limit.
Pressure B exceeds user-defined
dispense pressure limit.
Pressure A exceeds user-defined
dispense pressure limit.
Pressure B exceeds user-defined
dispense pressure limit.
Solution
Check feed system for low or empty
material.
Increase dispense rate.
Check pressure settings on setup
screen.
Check feed system for low or empty
material.
Increase dispense rate.
Check pressure settings on setup
screen.
Check feed system for low or empty
material.
Check feed system filters for
blockage if installed.
Check for blockage in feed system.
Check pressure settings on setup
screen.
Check feed system for low or empty
material.
Check feed system filters for
blockage if installed.
Check for blockage in feed system.
Check pressure settings on setup
screen.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
Check settings on feed system,
decrease pressure if necessary.
Check pressure settings on setup
screen.
Troubleshooting
31