en
Clean product and disinfect if necessary!
ƒ
Dirt fosters the formation of germs.
–
Encrustations may lead to the impeller be-
–
coming blocked.
1.7
Installation
Wear protective equipment!
ƒ
Do not install damaged or defective products.
ƒ
If there is a risk of germ formation, observe
ƒ
the following points:
Ensure sufficient air exchange.
–
Wear a breathing protection mask e.g. 3M
–
Series 6000 with filter 6055 A2
1.8
Electrical connection
Do not connect products with a damaged
ƒ
connection cable! Have the connection cable
replaced by a qualified electrician or the cus-
tomer service.
Mains connection with correctly installed pro-
ƒ
tective earth conductor.
8
Install the residual-current device (RCD) with
ƒ
30 mA.
Fuse protection at mains connection: max.
ƒ
16 A.
Product without plug: Electrical connection
ƒ
must be carried out by a qualified electrician!
1.9
During operation
The pumping of highly inflammable and ex-
ƒ
plosive fluids (petrol, paraffin, etc.) in their
pure form is strictly prohibited!
If persons come into contact with the pumped
ƒ
fluid (accessible basins*), do not commission
the product.
*Definition of "accessible basins"
Installation sites that can be walked on and dir-
ectly accessed without tools (e.g. ladders):
Garden ponds
ƒ
Paddling pools
ƒ
Cesspools
ƒ
Fountains, etc.
ƒ
WILO SE 2021-01
Need help?
Do you have a question about the Wilo-Rexa MINI3 Series and is the answer not in the manual?