Transport and storage
CAUTION
Soaked packaging may tear!
The product may fall on the ground if unprotected and
may be damaged. Lift wet packaging carefully and replace
it immediately!
ƒ
Wear protective equipment!
ƒ
Carry the pump by the handle. Never carry or pull on the
connection cable!
ƒ
Clean the pump and disinfect if necessary.
ƒ
Close the discharge connection.
ƒ
Protect the connection cable against kinking and damage.
ƒ
Use original packaging for transport and storage.
ƒ
Pack the pump when dry. Wet or humid pumps may soften
the packaging.
ƒ
Storage conditions:
–
Maximum: -15 ... +60 °C (5 ... 140 °F), max. humidity:
90 %, non-condensing
–
Recommended: 5 ... 25 °C (41 ... 77 °F), relative humid-
ity: 40 ... 50 %
Installation and operating instructions Wilo-Rexa MINI3
5
Installation and electrical connection
5.1
Installation types
ƒ
Stationary wet well installation
ƒ
Portable wet well installation
The following installation types are not permitted:
ƒ
Dry well installation
ƒ
Horizontal installation
5.2
Installation
ƒ
Wear protective equipment!
ƒ
Do not install a damaged or defective pump.
ƒ
Frost-free location.
ƒ
Lay the connection cable properly. During operation there
must be no danger (stumbling, damage, etc.).
ƒ
Float switch must be able to move freely!
en
15
Need help?