Wilo -Rexa MINI3 Series Installation And Operating Instructions Manual page 18

Table of Contents

Advertisement

en
Stand-alone inverters are used in autonomous power
supplies, e.g. solar power supply, and can generate over-
voltages. Overvoltages can destroy the pump.
ƒ
A multiple plug socket or power strip is in use
ƒ
An energy-saving plug is in use
This reduces the energy supply to the pump and the pump
may heat up too much.
5.3.1
Connection: Pump with plug
Provide a socket outlet with earthing contact. To connect
the pump, insert the plug into the socket.
NOTICE
Pump starts up or is ready for operation!
Once the plug is connected to the socket, the
pump will either start immediately or be ready
for operation:
• Pump without float switch: pump switches
on immediately!
• Pump with float switch: pump is ready for
operation and will switch on depending on
the fill level!
▶ We recommend switching the socket on
and off using a separate main switch!
18
5.3.2
Connection: Pump without a plug
DANGER
Risk of death due to electrocution!
Improper conduct when carrying out electrical
work can lead to death due to electric shock!
Electrical work must be carried out by a quali-
fied electrician in accordance with the locally
applicable regulations.
CAUTION
Irreparable damage as a result of water penetra-
tion
Connection cables without plugs feature bare cable ends.
Water may penetrate the connection cable and pump via
these bare cable ends. This will destroy both the connec-
tion cable and the pump. Never immerse the bare end of
the connection cable in fluid. Firmly seal it during storage.
The pump has a connection cable with bare cable end. The
pump must be permanently connected to a switchgear. Ob-
serve the following points:
ƒ
Earth the device properly!