Wilo -Rexa MINI3-V05-AU Series Installation And Operating Instructions Manual

Wilo -Rexa MINI3-V05-AU Series Installation And Operating Instructions Manual

Submersible pupm

Advertisement

Quick Links

Pioneering for You
Wilo-Rexa MINI3-V05...-AU
en Installation and operating instructions
·
3117617 • Ed.01/2022-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wilo-Rexa MINI3-V05-AU Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilo Wilo-Rexa MINI3-V05-AU Series

  • Page 1 Pioneering for You Wilo-Rexa MINI3-V05...-AU en Installation and operating instructions · 3117617 • Ed.01/2022-01...
  • Page 2 Rexa MINI3-...-AU https://qr.wilo.com/9405...
  • Page 3: Table Of Contents

    10.2 Oil change ................ 11 10.3 General overhaul .............. 11 11 Faults, causes and remedies............ 11 12 Disposal .................. 11 12.1 Information on the collection of used electrical and elec- tronic products .............. 11 12.2 Oil .................. 12 Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 4: Safety

    Clean and disinfect the product thoroughly • NOTICE! after removal! Useful information on handling the product • Inform all persons about the pumped fluid and Symbols the danger it poses! These instructions use the following symbols: Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 5: Transport And Storage

    Observe the following about commercial • Garden ponds use: • Paddling pools • These installation and operating instructions do not contain the necessary information for • Cesspools commercial use. • Fountains, and so on. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 6: 1.12 Operating Fluid

    52 mm (2 in) Operating mode, immersed Operating mode, non-im- S3 15% mersed Non-immersed: operating time 1,5 min Non-immersed: shutdown time 8,5 min Fluid temperature 3 ... +40 °C (37 ... 104 °F) Max. immersion depth 7 m (23 ft) Protection class IP68 Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 7: Type Key

    For the pumping in household (domestic) areas of: • Horizontal installation • Sewage without faeces – Wash basins Installation – Shower basins/bathtubs • Wear protective equipment! – Washing machines • Do not install a damaged or defective pump. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 8: Electrical Connection

    Connect the prepared pipe to the pressure pipe (for example, using a flexible hose section). Mount the connection cable at the pressure pipe and lay it to the socket/power supply. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 9: Connection: Pump Without Plug

    • The blue wire replacing the old black wire. Switch on level is reached: pump starts. • The brown wire replacing the old red wire. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 10: During Operation

    Oil types (ISO VG class 32): – ELFOLNA DS 22 Unscrew the pipe from the discharge port. – Shell Turbo T 32 Coil up the connection cable and store it with the pump. Clean pump and pipe thoroughly. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 11: Oil Change

    Shut down the pump, remove it and clean it. Note the following points for proper handling, recycling, and dis- posal of the product: Float switch not operational. ⇒ The float switch must be able to move freely. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...
  • Page 12: Oil

    Oil is harmful to health and the environment! Do not dispose oil with domestic waste or in the sewage system! Collect the oil in a sealable, oil-resistant container and dispose it at a certified collection point. Installation and operating instructions • Wilo-Rexa MINI3-V05...-AU • Ed.01/2022-01...