Save To Eeprom; Changes In Measurement Mode Without Save To Eeprom - Leister axetris LGD Compact Series Operating Instructions Manual

Laser gas detection oem module
Table of Contents

Advertisement

31 – 34
00 00 80 BF
35 – 38
0A D7 23 3C
39 – 42
00 00 20 41
43 – 46
00 80 BB 44
47 – 50
33 33 73 3F
51 – 54
00 00 80 3F
55 – 58
00 00 00 00
59 – 62
00 00 00 40
63 – 66
00 00 00 00
67 – 70
00 00 00 00
71 – 74
00 00 00 00
75 – 78
00 00 00 00
79 – 80
A2
7D
As confirmation, the device responds with a
Please note that this general description may be subject to changes depending on single product
execution.

Save to EEPROM

Changing the user parameter just stores them in the RAM. To save them from RAM to EEPROM use the save
command.
Command in Hex
Command in ASCII
As a confirmation, the device responds with a
The write cycles of an EEPROM are limited depending on external conditions. Under unfavorable
conditions the write cycles might be limited to 10,000 only.
3.5.5.1

Changes in Measurement Mode without Save to EEPROM

The switch from single gas to dual gas measurement for the execution LGD Compact CH
done several times a day during a normal operation in the field. Using the Save to EEPROM command after
every change would shorten the lifetime of the sensor module seriously due to the limited writing cycles of the
EEPROM.
The change from single gas to dual gas measurement can be done simply by sending the "Idle" command
following by the "Configure" command (3.5.4) and starting the measurement. The changes will be kept in the
configuration until the next power disruption of the sensor module.
For the execution LGD Compact CH4/C2H6 it is important not to send Save to EEPROM command
when changing the Measurement Mode from single gas to dual gas measurement to avoid a shorter
a lifetime due to limited writing cycles of the EEPROM.
Axetris AG
LGD Compact Operating & Integration Instructions; Rev. D
Analog output: Offset
Analog output: Span
Integration time
Concentration gas 2 Offset
Concentration gas 2 Span
Diagnostic Mode (1 = active / 0 = inactive)
For further details about Diagnostic mode, contact Axetris AG.
Reserved variable for future use (dummy)
Reserved variable for future use (dummy)
Reserved variable for future use (dummy)
Reserved variable for future use (dummy)
Reserved variable for future use (dummy)
Trailing zeros
End of packet with checksum
Config
-packet without any data.
7B 53 08 00 40 EA
{ S . . @ .
Save
-packet without any data.
(here: -1)
(here 0.01)
(here: 10)
(here 1500)
(here 0.95)
(here 1)
00
7D
.
}
/C
H
is normally
4
2
6
33/46