Micromatch connector J5 (20pol)

Be careful in case of connecting J5 directly because there is no protection circuit implemented on
the main board! The protection circuit is placed on the interface board.
Table 3 Connector assignment 20pol Micromatch
Pin
Power
1
Supply
2
3
Digital
4
Interfaces
5
Digital
13
Alarms
15
14
20
Analog
10
Interface
16
11
12
Not used
6...
9
17...
19
* connected on main board
** same potential
Axetris AG
LGD Compact Operating & Integration Instructions; Rev. D
Name
5V*
5V*
3.7V
TXD TTL
RXD TTL
ALARM 1
ALARM 2
ALARM 3
ALARM 4
DAC ANALOGOUT
HW INTERFACE PCB
GND**
GND**
n/a
n/a
Figure 11 Connector assignment Micromatch 20pol
Ordering number receptacle:
Manufacturer:
Description:
Article number:
Description
Power supply input for mainboard
Power supply input for mainboard
Power supply output 3.7V from mainboard to drive digital
hardware on interface board; not used in case of removing
the interface board
UART serial communication TTL-Level
UART serial communication TTL-Level
Signal for alarm 1 from Microcontroller, contact Axetris if
needed
Signal for alarm 2 from Microcontroller, contact Axetris if
needed
Signal for alarm 3 from Microcontroller, contact Axetris if
needed
Signal for alarm 4 from Microcontroller, contact Axetris if
needed
Analog output signal (0...2.5V) from Microcontroller, contact
Axetris if needed
Input for identification of interface board, connect to GND in
case of removing the interface board
Ground
Ground
n/a
n/a
TE connectivity
MICRO-MATCH MOW.20P
9-215083-0