Electrical Connection - Zanussi U33008 ZOB 330 User Information

Zanussi built-in-oven user manual
Table of Contents

Advertisement

Electrical Connection

The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L -
Live terminal
Letter N-
Neutral terminal
or E
-
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
Connection
Min. size
via
Cable/flex type
13 A socket
2.5 mm
outlet
13 A spur box
Oven
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/
flex
2.5 mm
2
26
Earth terminal
Cable / flex Fuse
2
3 core
butyl
insulated
2
PVC/PVC
twin and
earth
Cable / flex type
Fuse
H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load
in compliance with the current rules.
The switch must not break the yellow and green
earth cable at any point.
the yellow and green earth cable should be 2-3 cm
longer than the other cables.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 60°C above the ambient
temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load and that the power supply is properly earthed.
The manufacturer declines any responsibility
should these safety measures not be carried
out.
13 A min.
15 A min.
20 A max.

Hide quick links: