Download Print this page
Allegion LOCKNETICS NC450 Series Installation Instructions

Allegion LOCKNETICS NC450 Series Installation Instructions

Electric strike

Advertisement

Available languages

Available languages

Quick Links

Specifications
NC450 series of electric strikes are designed for use with cylindrical locksets and accommodate latchbolts up to 9/16" throw. The
strikes can be configured to fail-safe or fail-secure on site.
Operating Voltage
12VDC or 24VDC
(voltage non-polarized)
Voltage Tolerance
± 10%
Current Draw
Dual Voltage:
300mA/12VDC, 150mA/24VDC
Operating Temperature
For indoor use: 14°F to 120°F (-10°C to + 49°C)
Strike Humidity
0% to 85% Non-condensing
Latch Throw
9/16" (15mm) maximum
Keeper Width
1 7/16" (36mm)
Static Strength
1500 lbs (680Kg)
Dynamic Strength
70 ft-lbs
Endurance Test
250,000 cycles
Strike Body
Faceplate
Keeper
Latch Monitor
(when applicable)
Wiring Diagrams
Included in box:
(Square and Radius)
Red & Black: 12VDC
White & Red: 24 VDC
(Non-polarized)
For details regarding the limited warranty:
Customer Service
1-877-671-7011
www.allegion.com/us
Electric Strike Installation Instructions
Latch
Model
Monitor
NC450
NC450-LBM
Optional Faceplates:
6 7/8" NCCFP-KIT
(US32D, US10B)
CAUTION
Overheated or burnt coils caused by incorrect voltage/wire
harness combinations will not be covered under warranty
Dual Voltage (Non-polarized)
Black
Black
White
Green
Red
Red
White
Red
Green
Black
White
Red
NC450 Series
Body
Latch
Construction
Throw
9/16"
Zinc Alloy
(15mm)
7 15/16" NCWFP-KIT
(US32D, US10B)
24 VDC
© Allegion 2019
47267374 Rev. 03/19-a

Advertisement

loading
Need help?

Need help?

Do you have a question about the LOCKNETICS NC450 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Allegion LOCKNETICS NC450 Series

  • Page 1 Dual Voltage (Non-polarized) Red & Black: 12VDC Black White & Red: 24 VDC Black White (Non-polarized) Green White Green 24 VDC Black White For details regarding the limited warranty: Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2019 47267374 Rev. 03/19-a...
  • Page 2 Ramp Options Installation on Wood and Hollow Metal Frame: Three ramp options included to better align ramp gap with latch. If necessary, remove faceplate and switch ramps. Determine which ramp is needed based on the centerline of the dead latch. Fail-Safe / Fail-Secure Reversible NOTICE Factory default...
  • Page 3 Instructions d'installation des gâches électriques de la série NC450 Spécifications Les gâches électriques de la série NC450 sont conçues pour être utilisées avec les serrures cylindriques complètes et s'adaptent aux pênes demi-tour allant jusqu'à 1,42 cm (9/16 po). Les gâches peuvent être configurées sur le terrain pour Défaut Ouvert (FS) ou Défaut Fermé...
  • Page 4 Choix de rampe Installation sur cadre en bois et en métal creux : Trois choix de rampe sont inclus pour mieux aligner l'écart entre la rampe et le pêne. Si nécessaire, retirer la têtière et changer de rampe. Choisir la bonne rampe en fonction de l'axe central du pêne demi-tour à...

This manual is also suitable for:

Locknetics nc450Locknetics nc450-lbmLocknetics nc450 us32dLocknetics nc450-lbm us32d