Download Print this page
Allegion SCHLAGE S-6500 User Manual

Allegion SCHLAGE S-6500 User Manual

Touchpad digital door lock with fingerprint reader

Advertisement

Quick Links

S-6500
TOUCHPAD DIGITAL
WITH FINGERPRINT READER
USER MANUAL
Notice
Please read this manual before installation and operation.
Product composition and components
Screws
Optional parts
Communication pack
Remote key 
(RXP-10)
(RP-20)
Safety precautions
Do not disassemble or alter the lock.
Disassembling the door lock may damage the product. Damage to
the product caused by unauthorised persons may void the warranty.
Please keep the product away from water or any
liquids.
If the product is exposed to water or liquids, please wipe the
moisture off with a soft cloth. If moisture or foreign materials
penetrate the product, remove the batteries immediately.
Please check the batteries every 6 months for
leaks/cleanliness.
If leakage is discovered, please wipe out with a dry cloth and replace
with new batteries. In case of exposure to leakage, wash affected
skin area with soap and water immediately.
Do not clean the product with fl ammable
materials such as alcohol, benzene or thinners.
DOOR LOCK
Such materials may damage the surface of the lock or cause a fire.
Batteries should not be exposed directly to heat
sources or submerged in water, because they
may leak or explode, resulting in severe damage.
Do not use damaged batteries.
Do not allow the battery electrodes to make
contact with metals such as keys, as the battery
may overheat, causing an explosion or severe
damage.
Please do not close the door with the deadbolt in
the locked position.
It may damage the product or cause a malfunction.
Do not mix old and new batteries, or use different
types of batteries.
Ensure the + and - ends of the batteries are positioned correctly.
Incorrect positioning may cause leaks and/or an explosion.
Name
Front Ass`y
Back Ass`y
Back bracket
Mortise lock
Strike
Card / Fob
Emergency key
Key tail plate
Handle shaft
Handle shaft clip
Battery
Screws
User manual
Installation template Using for making hole at the door
Communication pack Communication pack
Remote key
※ Installation condition Door thickness 40~90mm
 H igh
temperature
warning
User
manual
Installation
template
Factory setting
Item
Auto/Manual lock mode
Language (English/Chinese)
Normal mode / Security Mode
Voice guide volume (1~3 level)
Beef sound level (1~8 level)
Product specification
Remark
Including rubber
86.6mm(W) X 331mm(H) X 30mm(D)
pad
82mm(W) X 310mm(H) X 33.7mm(D)
Including rubber
88mm(W) X 316mm(H) X 9.2mm(D)
pad
105.4mm(W) X 240mm(H) X 24mm(D)
24mm(W) X 240mm(H) X 4.5mm(D)
ISO card, Tag key, Mobile tag key
3 EA
1 EA
101.7mm(W) X 8mm(H) X 8mm(D)
2 EA
1.5V 'AA' Size LR6 Alkaline, 8ea(DC 6V)
1 set
Main User manual
Optional
Optional
Remote key
ㆍWorking temperature : -15~55 C
ㆍSensor working temperature(high): 60 C +- 5 C
If a high temperature is detected that may cause a fire, the
alarm will sound with a beeping sound for safety reasons.
If the Inside body is exposed to direct sunlight for a long
time and exceeds the set temperature, a beep will be
generated to protect the user. High temperature detection
also works with Double locking function.
Setting Status
Ref.page
[Auto lock]
8
English
11
Normal mode
9-10
3 level [Maximum]
7
8 level
7
Product features
Three way solution. (PIN code, Card / Fob,
fingerprint)
Available to use PIN code as well as Card / Fob and fingerprint.
Voice guide and 3 step volume control system
Voice guide (operation status, menu selection.) and provide 3 step
volume control system.
A ↔ M automatic / manual locking set function
Automatic and manual locking mode set is possible with simple
switch operation from Inside.
Auto relock function
If users do not open the door after unlocking the device it will lock
itself automatically.
Double lock function
When double lock function is activated, the door cannot be opened
from the outside, even with the registered card, PIN code or
fingerprint. Override key can still be used.
Mute function
Door will not emit any sound when mute is activated.
Battery level indicator and alarm for battery
replacement
Easy to check battery status with three step level indicator and
alarm when battery replacement is required.
Trespass alarm function
When the door is opened by force an alarm will sound.
Prevent trespass and hacking
After multiple incorrect attempted entries an alarm will sound and
all the functions of the lock will be suspended for three minutes.
The alarm activates after three incorrect PIN/card entries and five
incorrect fingerprint entries.
Random security coding
When you enter your home with other people, you may not want
to show your PIN code to them. In this case, you may press any
numbers randomly and then enter your PIN code at the end and you
will still gain access.
Normal mode/safety mode
Normal mode is ideal for new users or low security environments
Safety mode provides a higher security level via use of a manager
PIN code. Allows individual register and delete function which is not
provided in normal mode.
Name and function of each part
1. Front Ass`y
Finger print sensor
Touch the registered fingerprint on sensor and
Card / Fob touch plate
then open the door.
Touch the registered Card / Fob to
Status indicator
open the door.
Lock / Unlock lamp
Indicate lock / unlock status.
Touch type numeric pad
External emergency power
supply terminal
when battery does not operate, product may
be operated and unlocked by contacting 9V on
terminal located outside.
Handle
Emergency key
Can open the door by pushing
down it after pressing PIN code
open the door with emergency key by manual.
or touching Card / Fob or
fingerprint.
Status indicator
Window icon
Indicate operation status and
Mute function
checking battery capacity.
Double lock function
Remaining battery 20%
Wireless interlock
Remaining battery 50%
Battery replacement indicator
Trespass alarm function
Remaining battery 80%
2. Back Ass`y
Battery cover
Push up to open the battery cover.
 [ N], [S], [
] Button
Communication pack socket
Indicator lamp
Manual locking button
[Double lock function]
Button to lock the door by manual at
Slide switch
manual locking mode.
Handle
Can open the door at anytime only by
pulling down this handle.
[N], [S], [
] button
Auto/Manual mode switch
N :  R egistration / delete of PIN code, Card
Auto lock
/ Fob,fingerprint in normal mode
[Auto lock]mode, door will be locked
S :  R egistration / delete of PIN code, Card /
automatically after closing.
Fob, fingerprint in safety mode
Manual lock
 ( Communication function) :
[Manual lock] mode, door will be locked with
To register or delete optional
pressing manual lock button after closing.
communication module
Window icon
 A uto / Manual mode switch

Advertisement

loading
Need help?

Need help?

Do you have a question about the SCHLAGE S-6500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Allegion SCHLAGE S-6500

  • Page 1 Safety precautions Product features Three way solution. (PIN code, Card / Fob, Do not disassemble or alter the lock. fingerprint) Disassembling the door lock may damage the product. Damage to Available to use PIN code as well as Card / Fob and fingerprint. the product caused by unauthorised persons may void the warranty.
  • Page 2 [Unlock] button ㆍ ㆍ ㆍ REG. Card / Fob 1.5v ‘AAA’ size  alkaline  Allegion (NYSE:ALLE) is a global pioneer Fingerprint battery 1 ea All  in safety and security, with leading Card / Fob When purchasing wireless communication ※...