Connection Diagram For 400 V 3N; Connection Diagram For 230 V - Harvia sentiontec Concept R mini Series Instructions For Installation And Use Manual

Sauna heater
Table of Contents

Advertisement

4.5. Connection diagram for 400 V 3N~

Fig. 8
Connection diagram for the Concept R mini
3.5 kW, 4.5 kW, 6.0 kW and 7.5 kW
(CP-RM-35 / CP-RM-45 / CR-RM-60 / CP-RM-75)
L1 L2
L3
N
4
L1
L2
L3
N
PE
400V 3N~

4.6. Connection diagram for 230 V 3~

Fig. 9
Connection diagram for the Concept R mini
3.5 kW, 4.5 kW and 6.0 kW
(CP-RM-35 / CP-RM-45 / CR-RM-60)
L1 L2
L3
4
L1
L2
L3
PE
230V 3~
U V
W
N
N
U V
W
N
N
W
V
U
3
U V
W
N
N
U V
W
N
N
W
1
1
*
N
V
U
3
r r
w
w
2
r r
w
w
2