Maintenance; Cleaning The Sauna Heater; Changing The Sauna Stones - Harvia sentiontec Concept R mini Series Instructions For Installation And Use Manual

Sauna heater
Table of Contents

Advertisement

Instructions for use for the user

7. Maintenance

7.1. Extended periods of non-use
Moisture can accumulate in the heating rods in humid ambient conditions or
during long periods of non-use. This is a physical process and not a manufactur-
ing fault. Accumulation of moisture in the heating rods can lead to the FI circuit
breaker being triggered. In this case, contact an electrician to correct the fault
(see chapter 9. Problem-solving by the installer).
tended periods of non-use.

7.2. Cleaning the sauna heater

Make sure that the ventilation openings are free of lint and dust. This prevents
the air circulation in the sauna heater from being restricted and prevents the
device from overheating.

7.3. Changing the sauna stones

Sauna stones are subject to stress by the water poured on them, and by large
come weak and brittle.
Check the sauna stones at regular intervals and replace the stones at least
once a year.
WARNING!
If the sauna heater is used without sauna stones, the cabin walls will
NEVER operate the sauna heater without the sauna stones.
p. 23/28
-