Page 1
CAT.ES100-52 ® 2-colour Display Type Digital Pressure Switch ISE70/75/75H Series Rated Pressure Rated Pressure General General · · Fluids Fluids (ISE75) (ISE75H) For Air For Air 2-colour 2-colour (ISE70) IP67 IP67 digital digital 2-colour Display (green and red) • Selectable from four patterns green green green...
Digital Pressure Switch ISE70 Series For Air Specifications ISE70 Rated pressure range 0 to 1MPa Set pressure range –0.1 to 1MPa Proof pressure 1.5MPa Set pressure resolution 0.01MPa Fluid Air, lnert gas, Non-flammable gas Power supply voltage 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Current consumption 55 mA or less (at no load) Note 1)
2-colour Display Digital Pressure Switch/For General Fluids ISE75/75H Series ® How to Order ISE75 10MPa ISE75H 15MPa Piping Option 2 Rc1/4 NPT1/4 None Note 1) G1/4 (ISO1179) With bracket Note 1) G1/4: Applicable to ISO1179-1 Output Fixed setting: NPN open collector 1 output (Pin no. 4) + PNP open collector 1 output (Pin no.
Page 5
Digital Pressure Switch ISE75/75H Series For General Fluids Specifications ISE75 ISE75H Rated pressure range 0 to 10MPa 0 to 15MPa Set pressure range 0.4 to 10MPa 0.5 to 15MPa Proof pressure 30MPa 45MPa Set pressure resolution 0.1MPa Fluid Fluid that will not corrode stainless steel SUS430 and SUS630 Power supply voltage 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Current consumption...
Page 6
ISE70/75/75H Series Description Indication light (Green) LCD display Displays the switch operation status. Displays current pressure condition, set mode and error code. The display mode can be selected from four options: fixed green OUT1 single-colour reading, fixed red SET button DOWN single-colour reading,...
Page 7
Digital Pressure Switch ISE70/75/75H Series For Air/For General Fluids Dimensions ISE70 75 75H Piping port 02: Rc1/4 N02: NPT1/4 F02: G1/4 (ISO1179) Lead wire with M12 OUT1 connector (5m) DOWN straight Note) The connector faces down (toward the piping). Do not attempt to rotate the connector, as it is not rotatable.
ISE70/75/75H Series Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of "Caution", "Warning", or "Danger". To ensure safety, be sure to Note 1) Note 2) observe ISO 4414 , JIS B 8370...
Page 9
ISE70/75/75H Series Pressure Switch Precautions 1 Be sure to read before handling. Design and Selection Wiring Warning Warning 1. Verify the colour and terminal number when 1. Operate the switch only within the specified voltage. wiring. Use of the switch outside the range of the specified voltage can Incorrect wiring can cause the switch to be damaged and cause not only malfunction and damage of the switch but also malfunction.
Page 10
ISE70/75/75H Series Digital Pressure Switch Precautions 1 Be sure to read before handling. Pressure Sources Selection Warning Warning 1. Monitor the internal voltage drop of the switch. 1. Use the switch within the specified fluid and ambient temperature range. When operating below a specified voltage, it is possible that the load may be ineffective even though the pressure switch Take measures to prevent moisture from freezing in circuits function is normal.
Page 11
When connecting the pipe to the switch, apply a torque of occur due to noise from these other lines. 13.6 N·m or greater for the ISE70 series and a torque of 25 4. If a commercial switching regulator is used, N·m or greater for the ISE75/75H series.
Page 12
ISE70/75/75H Series Specific Product Precautions 2 Be sure to read before handling. Refer to pages 7 through 9 for safety instructions and pressure switch precautions. Set pressure range and rated pressure range Caution Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting.