Specifications
Rated pressure range
Set pressure range
Proof pressure
Set pressure resolution
Fluid
Power supply voltage
Current consumption
Switch output
Max. load current
Max. applied voltage
Residual voltage
Response time
Short circuit protection
Repeatability
Hysteresis mode
Hysteresis
Window comparator mode
Display
Display accuracy
Indication light
Functions
Enclosure
Fluid temperature range
Environ-
Operating temperature range
mental
Operating humidity range
resistance
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Temperature characteristics
(Based on 25°C: Operating temperature range)
Standard
Wetted material
Port size
Lead wire
Mass (Weight)
Note 1) The NPN and PNP outputs function for a single set point.
Note 2) G1/4: Applicable to ISO1179-1
Internal Circuit and Wiring Examples
Fixed setting:
NPN open collector output + PNP open collector output
(the pressure set point for switching the output signal is common to both outputs.)
Maximum 30 V (NPN only), 80 mA, Residual voltage 1 V or less
Output -43
DC (+)
(Brown)
OUT1 (NPN)
(Black)
OUT1 (PNP)
(White)
DC (–)
(Blue)
12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection)
Output -43: Fixed setting; NPN open collector 1 output (Pin no. 4) + PNP open collector 1 output (Pin no. 2)
Output -65: PNP open collector 1 output (Pin no. 4)
2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms)
3 ditit, 7-segment indicator, 2-colour display (red and green) can be interlocked with the switch output, Sampling cycle: 5 times/s
Anti-chattering function, Unit display switching function, Zero out function, Key lock function
Operating: 0 to 50°C, Stored: –10 to 60°C (with no freezing or condensation)
Operating and stored: 35 to 85%RH (with no condensation)
1000 VAC for 1 min. between live parts and enclosure
50 MΩ or more between live parts and enclosure (at 500 VDC Mega)
10 to 500 Hz, 1.5 mm or 98 m/s
980 m/s
Compliant with CE Marking and UL/CSA (UL508) standards
Fitting: C3602 (electroless nickel plated), Sensor port: PBT, Sensor pressure receiving area: silicon, O-ring: NBR
02: Rc1/4, N02: NPT1/4, F02: G1/4 (ISO1179)
Lead wire with M12 4-pin pre-wired connector (5 m)
190 g (excluding the lead wire with M12 4-pin pre-wired connector)
Load
+
12 to
24 VDC
–
Load
Digital Pressure Switch
For Air
ISE70
0 to 1MPa
–0.1 to 1MPa
1.5MPa
0.01MPa
Air, lnert gas, Non-flammable gas
55 mA or less (at no load)
80 mA
30 V (with NPN output)
1 V or less (with load current of 80 mA)
With short circuit protection
±0.5%F.S.
Adjustable (can be set from 0)
±2%F.S. ±1 digit or less (at 25°C ±3°C)
Light up when output is ON (Green)
IP67
0 to 50°C (with no freezing or condensation)
2
amplitude in X, Y, Z directions for 2 hours each
2
in X, Y, Z directions 3 times each (Non energized)
±2%F.S. or less
See the operation manual for information on how to
set and on handling precautions.
Output -65
ISE70
Series
Note 1)
Note 2)
DC (+)
(Brown)
N.C.
(White)
+
12 to
24 VDC
OUT1 (PNP)
–
(Black)
Load
DC (–)
(Blue)
Note 1)
2