Download Print this page
Groz EOP Series Instruction Manual

Groz EOP Series Instruction Manual

Electric oil and fuel pump

Advertisement

Quick Links

INSTRUCTION MANUAL
Electric Oil and Fuel Pump
EOP
Congratulations on purchase of this World Class Electric Oil and Fuel Pump!
• Vertical mount fuel and oil pump for light use
in Industrial, Automotive, Heating and Marine
applications.
• Equipped with a centrifugal electric motor
with double insulation making it safe for use
with water and emulsions.
• Manufactured from chemically inert
materials.
• Comes with a Bent Spring Device to prevent
the outflow of media due to Siphon action in
case of accidental damage to the delivery
hose or dispensing nozzle.
• Built in 2" Bung adaptor to fit on most of the
drum sizes.
PART DESCRIPTION
REFERENCE NUMBER
1
2
3
4
5
6
7
DESCRIPTION
Pump Body ( including component 8 & 10 )
4 meter X 3/4" rubber hose (to be cut as required)
Dispensing Nozzle [ including trigger (9) ]
Intake Filter
Stainless Steel Tube
Hose Clamps
Bent Spring Device
Bent Spring Device
3
Dispensing
Nozzle
Trigger
6
Hose
Clamp
Rubber
2
Hose
1
S1510, REV A
7
9
4
Intake Filter
5
QUANTITY
1
1
1
1
1
4
1
10
On/Off Switch
1
Pump Body
8
Lever
Stainless Steel
Tube

Advertisement

loading
Need help?

Need help?

Do you have a question about the EOP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Groz EOP Series

  • Page 1 INSTRUCTION MANUAL S1510, REV A Electric Oil and Fuel Pump Congratulations on purchase of this World Class Electric Oil and Fuel Pump! Bent Spring Device • Vertical mount fuel and oil pump for light use in Industrial, Automotive, Heating and Marine On/Off Switch applications.
  • Page 2 PUMP SPECIFICATION DESCRIPTION EOP/DC/12 EOP/DC/24 EOP/AC/110 EOP/AC/230 Supply Voltage 12V DC 24V DC 110V AC 230V AC Max. Flow Rate Upto 9.25 GPM Upto 9.25 GPM Upto 10.5 GPM Upto 10.5 GPM (35 LPM) (35 LPM) (40 LPM) (40 LPM) Electric Motor 0.43 HP 0.43 HP...
  • Page 3 Assemble the filter (3) on the suction hose and • The motor and switch are not of an anti-explosive type. Do fasten in place not use the pump in areas where there is risk of explosion. with a hose clamp. • Do not use the pump for gasoline, inflammable liquids with PM <...
  • Page 4 EMERGENCY OPERATION In the case of power failure or when small quantities of liquid need to be transferred, it is possible to operate the pump manually, in the following manner: • Keep the trigger (9) of the dispensing nozzle pressed ; • Activate the lever (8) repeatedly ;...

This manual is also suitable for:

Eop/dc/12Eop/dc/24Eop/ac/110Eop/ac/230