Section Twelve Assemble The Appliance (Installation Instructions); Section Thirteen Check Operation Of Fire (Installation Instructions); Section Fourteen Instruct And Advise The Customer (Installation Instructions) - Charlton & Jenrick Paragon Core BF Remote Control Owner's Manual

Hide thumbs Also See for Paragon Core BF Remote Control:
Table of Contents

Advertisement

SECTION TWELVE Assemble the Appliance (installation instructions)

Position the refractory fuel bed components as described in section four of this manual, it is important that the
fuel bed is positioned exactly as described to ensure the correct operation of the appliance. Badly positioned fuel
bed components may result in the gas flame being driven forward onto the glass and permanently marking it.
Slide the top of the Glass Frame under the Glass Frame Bracket on the fire and centralize the slots over the Four
fixing studs, making sure the seal inside the glass.
Start the nuts on these four studs.
Tighten the Four nuts up evenly ensuring that the glass compresses the seal on all four sides.
Position the fret apron and secure with two nuts.
Position the grill fascia so that it hooks centrally over the top flange of the combustion box and covers the front
edge of the glass frame.
Position four magnets in two up each side of the appliance flange, and offer the decorative trim up squarely and
centrally.

SECTION THIRTEEN Check Operation of Fire (installation instructions)

CHECK BURNER PRESSURE AND GENERAL OPERATION
Remove the screw from the pressure test point on the inlet elbow and fit a pressure test gauge.
Purge the air from the appliance by operating the appliance (see Section 3). The appliance will spark for
approximately 20 second at which point if no ignition is detected the appliance will go to lock out and you must
repeat the ignition procedure.
Check that the electrode is sparking at the gap between the thermocouple tip and the electrode and that the pilot
ignition is established. After approximately 20 seconds the main burner will light on the high setting.
Check that the inlet pressure 20mbar +/- 1 mbar for natural gas or 37mbar +/- 1 mbar for L.P.G.
Refit pressure test point screw and check for leaks.

SECTION FOURTEEN Instruct and Advise the Customer (installation instructions)

Demonstrate the lighting and extinguishing procedure to the consumer/user and the removal and refitting of the
decorative trim for cleaning.
Explain that for the first few hours of the fire operating there will be an initial odour. This is due to the curing of
the paint, the appliance should be operated on its high setting, and it is recommended that a window is left open
until that odour has completely disappeared.
Instruct on the glass removal and refitting.
Instruct on the fuel bed cleaning and advise that a vacuum cleaner can be used but only after all the loose fuel
bed shapes have been removed. Refer to 'Health & Safety Notice (See Section One) at the front of this booklet
before proceeding.
Advise that the appliance should be serviced annually by a competent person i.e. a Gas Safe registered engineer
in accordance with these instructions.
Although the appliance is fitted with a glass front which acts as a dress guard it is strongly recommended that a
fireguard should be used for the protection of children, the elderly or infirm. Fireguards should conform to B. S.
6539 (1984) (Fireguards for use with solid fuel appliance).
Hand these instructions to the user.