Apply Rail Assembly; Cylinder Installation; Door Preparation - Assa Abloy SARGENT 5300 Series Installation Instructions Manual

Alarmed exit devices
Table of Contents

Advertisement

5300 Series
Alarmed Exit Devices
Installation Instructions
6

Apply Rail Assembly

1. Depress lift arm into rail assembly and slide rail onto chassis.
2. Attach rail assembly to chassis with two (2) #8 truss head machine screws. Do not tighten screws
(Figure 9).
3. Secure chassis to door with four (4) #10 flat head screws. (Figure 8)
4. Level rail.
5. Place mounting plate tight against rail and attach to door with two (2) #10 round head screws.
6. Tighten all screws securely (Figure 10).
Lift Arm
Mounting Plate Screws
(#10-24 x 3/4" PH. RD. HD. Machine Screw)
7

Cylinder Installation

a

Door Preparation

1. Prepare door according to template.
2. Verify size 41 cylinder is installed in rail insert with collar prior to installing exit device on door.
NOTE: Use caution not to dam age wires when installing cylinder nut.
1-800-727-5477 • www.sargentlock.com
Copyright © 2019, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in
part without the express written permission of SARGENT Manufacturing Company is prohibited.
Level
Mounting Plate
Rail Assembly
Rail Mounting Screw (2 Places)
(#8-32 x 3/8 PH. Truss HD. Machine Screw)
Figure 9
Figure 10
Collar
Mounting Plate
Figure 11
Cylinder nut
Figure 12
7
Chassis Mounting Screws
(1/4-20 x5/8 PH. FL. HD.
Machine Screws)
Four (4) places
Side View. Battery holder
not shown.
Use caution not to dam-
age wires when installing
cylinder nut.
A8255A 08/19