General Information About Using The Multi 2000 - PRONOVA Stelzner pH AGRAR 2000 Technical Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
GB
MULTI 2000
ART.-NO.
ACCESSORIES
4097
4-wire carbon conductivity electrode
pH glass insertion electrode made of glass
3011
with 3 diaphragms, 3 mole/l KCl
ph 4.0 buffer solution
3012
100 ml bottle
ph 7.0 buffer solution
3013
100 ml bottle
Calcium chloride (CaCl
0504
(approx. 11.1 g for 10 l solution 0.01 mole/l)
Calcium chloride (CaCl
0505
(approx. 100 g)
Refill solution with filler syringe for
3022
pH electrodes, 3 mole/l KCl, 100 ml bottle
3017
Dibble
3028
Cap for pH glass insertion electrodes
1023
AM probe (25 cm) with DIN-plug
Nitrate test strips
2005
Box with 100 strips
Calibration solution, 1.4 mS/cm
1303
100 ml bottle
Calibration solution, 12.88 mS/cm
1308
100 ml bottle
Calibration solution, 111.8 mS/cm
1304
100 ml bottle
Beaker for measuring volume, 100 ml
2014
with cover
1004
Spray bottle
3019
One nine-volt battery, size 6LR61
4444
Technical manual
40
4.1 General information
) for soil analysis
2
) for soil analysis
2
1. When determining the proper fertilizer solu-
about using the MULTI 2000
About this meter
The MULTI 2000 meets all the demands that
agricultural professionals can put on state-
of-the-art measuring equipment. The MULTI
2000 measures the pH, conductivity (up to
200 mS), activity or the temperature, depen-
ding on the connected probe.
The MODE button is used to toggle between
the different measurement probes. The CAL
button is used to calibrate the pH and EC
value. This meter does not need to be cali-
brated for activity measurements.
The MULTI 2000 is a professional-quality mul-
ti-functional meter. In order to achieve the
optimal measurement accuracy, this meter
should be calibrated regularly.
When measuring in the lower EC measure-
ment range, the lower range is also calibra-
ted. Similarly, high-calibration solutions are
used when taking preferred measurements
in the upper measurement range (one-point
calibration).
The pH glass insertion electrode is calibra-
ted with buffers of pH 4 and pH 7 (two-point
calibration).
The meter features temperature compensa-
tion. However, whenever it has been stored
under extreme temperatures, it should be
allowed to acclimate to the ambient tempe-
rature before the first measurement.
Information about EC, activity and pH
The optimal supply of plant nutrients is a key
requirement for successfully cultivating flori-
culture and crops. Thus, it is very important
to check guideline values such as pH, salinity
and conductivity. If a measurement is below
the guideline value, this indicates a possible
deficiency or root-damaging salt accumula-
tions caused by over-fertilization.
tion, the MULTI 2000 measures the conducti-
vity in EC (mS / cm) in the irrigation water and
in the liquid fertilizer. Please pay attention
to the requirements from the manufacturer
of the fertilizer and take into account the EC
value of the water you are using.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents