Two-Wire Edge Sensors With End Of Line (Eol) Resistor - Tapeswitch Safety Edge TS-26 Installation Manual

Table of Contents

Advertisement

Release 08/2020 Ver. 1.0
Installation Manual: Safety Edge

4.2.3.2 Two-wire edge sensors with end of line (EOL) resistor

Upon request, Tapeswitch offers all edge sensors in a two-wire (control reliable to meet safety performance level)
configuration. This configuration utilizes a single, two-wire cable at one end of the sensor and an appropriate EOL
resistor at the other. A suitable SIM (Tapeswitch PSSR/2) will provide a monitored system with safety outputs to
be interfaced to the machine control system as intended.
For applications that require an array of interconnected sensing edges and an end-of-line (EOL) resistor, all edge
sensor segments but the last must be of the 4-wire configuration. The last edge in the series must have the EOL
resistor at its output.
Note:
While utilizing the two-wire edge sensor with EOL resistor, the maximum resistance between actuator terminals
cannot exceed 8.7K ohms. This will render the sensing edge assembly incompatible with PSSR/2 model SIMs.
The complete manual for PSSR/2 can be found at the following link:
https://www.tapeswitch.com/support/downloads.html
PSSR/2, EOL resistor-terminated connection - Figure 5
For any questions regarding these configurations, please contact Tapeswitch at:
sales@tapeswitch.com
TAPESWITCH CORPORATION
8
100 Schmitt Boulevard
Farmingdale, New York, 11753
© 2020 Tapeswitch Corporation. All Rights Reserved