4. TECHNICAL DESCRIPTION

4.1 System Overview

Safety edge sensors are used to create a sensing area that may consist of a single edge or a combination of
edges. When the sensing edge is compressed to actuation, the (electrically closed) condition is detected by the
safety interface module (SIM). When appropriately configured, the (SIM) switches off its output relays and/or PNP
drivers, ideally causing dangerous motion to cease or be prevented.

4.2 Edge Sensor Design

4.2.1 Internal Construction

Each Tapeswitch sensing edge utilizes Controflex ribbon switch technology for its electrical switching
component. Each edge is designed to focus applied force (along the reference direction of the sensor) toward the
internal Controflex ribbon switch, thereby creating switch closure and supplying a signal to the SIM for evaluation
and "Stop" command.

4.2.2 Chemical Resistance

Tapeswitch safety edge sensors are constructed utilizing several material compounds. All materials are resistant
to chemicals commonly found in an industrial environment.
Please see the following table to determine the material best suited to your application. Upon request, Tapeswitch
can supply a small sample of edge material for your own chemical testing. Please contact
sales@tapeswitch.com
Sensing Edge Profiles
Material
Acetone Resistance
Aging Resistance
Alkali Resistance
Petrol Resistance
Diesel Resistance
Coolant Resistance
Mineral Oil Resistance
Ozone Resistance
Acid Resistance
Water Resistance
UV Stability
COVERAGE INDEX: 1 = Excellent, 2 = Very Good, 3 = Good, 4 = Moderate, 5 = Low, 6 = Insufficient

4.2.3. Combining of Sensors

When multiple edge sensors are used in combination, they must be wired in series, such that the SIM monitors
the entire array as if it were one normally-open switch. Actuation of any sensing edge segment will result in a
signal transition at the SIM's monitoring input.
TAPESWITCH CORPORATION
100 Schmitt Boulevard
Farmingdale, New York, 11753
Installation Manual: Safety Edge
with your request.
TS-26, TS-47, TS-48, TS-57, TS-67
Chemical Resistance Table - Figure 3
© 2020 Tapeswitch Corporation. All Rights Reserved
Santoprene
3
2
3
6
6
5
6
2
3
1
2
TS-18
TS-3, TS-8, TS-16
EPDM
PVC
6
6
3
3
2
2
6
6
6
6
5
5
6
6
3
3
2
2
1
1
2
2
6

Advertisement