Specifications; General - Tapeswitch Safety Edge TS-26 Installation Manual

Table of Contents

Advertisement

Release 08/2020 Ver. 1.0

9. SPECIFICATIONS

9.1 General

1) Effective Length (EL): The effective area of each edge defined in table below.
Note: For applications requiring "non-standard" EL, please contact Tapeswitch
engineering at 1-800-234-TAPE or by e-mail sales@tapeswitch.com
2) Sensor Switch: All Tapeswitch edge sensors use Controflex ribbon switch for actuation.
Ribbon switch devices consisting of a pair of metal conductor plates with an extruded jacket
of soft PVC.
3) Lead Wires: Tapeswitch edge sensors are available with several options regarding cable
style and exits. Not all edge sensors will have identical cable style depending on normal
standard (see
www.tapeswitch.com
requirements by the user. One (two conductor - with EOL resistor option), two (two
TAPESWITCH CORPORATION
100 Schmitt Boulevard
Farmingdale, New York, 11753
Installation Manual: Safety Edge
Effective length definition - Figure 18
for standard cable) and/or specific application
© 2020 Tapeswitch Corporation. All Rights Reserved