Presence sensor w/monitoring
Table of Contents

Advertisement

4
PROGRAMMING THE SENSOR (cont.)
REMOTE CONTROL SET-UP (cont.)
PARAMETER
Sensitivity
Hold Time
Output Configuration
Auto-Learn Time
Pattern Width
Pattern Depth
Immunity
Set-up
NOTES:
QUIET MODE: The QUIET mode uses a different pulsing pattern to avoid interference with other infrared systems. The NORMAL
mode transmits more energy and detects in a slightly crisper fashion.
PATTERN WIDTH & DEPTH: When pattern width or depth is changed, a set-up of the new pattern size will automatically be triggered
once a value key has been pressed.
THRESHOLD: The Threshold is always OFF when the door is closed.
AUTOMATIC SET-UP: When performing an automatic set-up (set-up key pressed twice), the sensor will begin to flash green during
the door-closed position, and will continue to do so until the door is activated to the open position. The LED will then go out and
the door will close. The LED will flash green again at the closed position until a set-up is complete. Upon the next activation, the
sensor will launch another set-up for the open-door position, and will begin normal operation thereafter.
Reducing Cross-Talk in Dual-Egress Applications
1. Ensure that the two sensors are installed with < 40" of separation between the two (measured from midpoint of each sensor).
2. Place doors in Hold Open position. Unlock the sensor and set open door Pattern Depth to 5 (medium pattern). IR threshold
will be off while in this door position. Be sure to change the setting on BOTH sensors.
3. Change IR frequency on one sensor.
4. If in an application with high-gloss floors or multiple doors installed in vestibules, change to different frequency.
Page 8 of 12
Specific Parameter Settings
0 (min)  9 (max)
0 (0.5 s)  9 (9 s)
1: Normally Open Relay
2: Normally Closed Relay
0: 30 seconds
4: 5 minutes
1: 1 minute
5: 7 minutes
2: 2 minutes
6: 10 minutes
3: 3 minutes
1: Wide (closed door)
2: Middle (open door)
3: Asymm. left narrow
4: Asymm. right narrow
5: Narrow left
See notes below for Pattern Width or Depth.
1: Deep – threshold ON
2: Medium – threshold ON (open)
3: Limited – threshold ON
See notes below for Pattern Width, Pattern Depth, and Threshold.
1: Low (normal)
2: Medium – Rain (disregards more floor disturbances)
3: High – Snow (disregards greatest floor disturbances)
For BOYDGUARD-TC functionality, set Immunity to High.
launch a quick set-up
restore factory defaults
SETTING
default 7 = door open
default 6 = door closed
7: 15 minutes
8: 10 seonds
9: Infinity (no learn)
6: Narrow right
7: Asymm. left wide
8: Asymm. right wide
9: Center narrow
4: Deep – threshold OFF
5: Medium – threshold OFF (closed)
6: Limited – threshold OFF
launch a closed-door set-up
launch an open-door set-up
See Automatic Set-up note.
75.5905.06 BODYGUARD-T 20190402