PROGRAMMING THE SENSOR (cont.)

PUSH-BUTTON SET-UP

Only the following functions are programmable using push-buttons:
• Sensitivity
• Output configuration
• Auto-learn time
• Pattern width
• Pattern depth
1
Press PB1 for less than 2 seconds. LED will flash green for 10 seconds and the sensor will execute the
appropriate set-up for the current door position. The green LED flashes at a slower rate if interruptions
are detected in the field. Press PB1 to re-launch.
2
Press PB1 for more than 2 seconds to change the parameters.
3
To choose the parameter, press either PB1 or PB2, and the LED will flash red (indicating the parameter)
and then flash a specific number of green blinks (indicating the current parameter setting). See chart
below for reference.
NOTES:
* Pressing PB1 will toggle between parameters.
* Pressing PB2 will toggle between range of adjustments for that particular parameter.
* The value returns to the lowest setting when PB2 is pressed again after reaching the highest adjustment.
* Zero value = no LED flash
* To exit, wait 20 seconds or press PB1 for more than 2 seconds.
4
When finished with manual set-up, replace the right end cap.
75.5905.06 BODYGUARD-T 20190402
Red LED
Parameter
Status
1 flash
1
2 flashes
2
3 flashes
3
4 flashes
4
5 flashes
5
6 flashes
6
7 flashes
7
8 flashes
8
Description
Sensitivity (door open)
Sensitivity (door closed)
Output configuration
Auto-Learn time
Pattern width (door open)
Pattern width (door closed)
Pattern depth (door open)
Pattern depth (door closed)
PB1
LENS
PB2
Green LED Status
0 – 9 flashes (default = 7)
0 – 9 flashes (default = 6)
1 – 2 flashes (default = 1)
0 – 9 flashes (default = 0)
0 – 9 flashes (default = 2)
0 – 9 flashes (default = 1)
1 – 6 flashes (default = 1)
1 – 6 flashes (default = 1)
Page 9 of 12