Sensor Installation - BEA BODYGUARD-T Manual

Presence sensor w/monitoring
Table of Contents

Advertisement

1
MECHANICAL INSTALLATION (cont.)

SENSOR INSTALLATION

MOUNTING DIRECTLY TO DOOR FRAME/HEADER:
Align the sensor with the chosen location and attach the sensor
1
using the two self-drilling screws (provided with kit). A pilot hole
in the header may be necessary to ease screw installation.
If the sensor is mounted directly to the header and the cabling will
2
pass directly through the header, drill a
to the left-side end cap. Ensure that the hole location aligns with
the end cap cut-out.
MOUNTING TO BODYMOUNT:
Route harness through wire passage hole while aligning the sensor
1
with the Bodymount.
Attach the sensor to the Bodymount using the two self-drilling
2
screws (provided with the kit).
REPLACE THE CIRCUIT BOARD:
Slide the circuit board back into the extrusion.
3
ANGLE ADJUSTMENTS:
Make any necessary angle adjustments after installation. Use the images below to aid in choosing angles.
Angles must match for each clip on the same PCB.
Should only be used when the sensor is
mounted to a Bodymount block or soffit
above the door that extends out from the
face of the safety side of the door. This
would improve the detection field location
across the threshold area of the doorway.
Page 4 of 12
" wire passage hole next
1
2
5° (FACTORY DEFAULT)
For most applications, it is recommended
that the unit be powered and walk-tested
at this angle. After walk-testing, the
detection field may be altered by adjusting
the angle (see directions below).
10°
75.5905.06 BODYGUARD-T 20190402

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents