BEA BODYGUARD-T Manual page 5

Presence sensor w/monitoring
Table of Contents

Advertisement

2
WIRING
WIRING TO MONITORED DOOR CONTROLS
1. Plug the 10-pin connector to the Bodyguard-T
using the provided cable. DO NOT USE the 7-pin
terminal – this is not designed to be used with
monitored systems.
Also verify that the monitoring DIP switch is set to
ON.
2. Hard-wire to the door control. Reference the table
below for connection points.
Position
Connection
1
12 – 24 VAC/VDC ±10%
2
12 – 24 VAC/VDC ±10%
3
Common
4
Normally Open
5
WIRING TO MODULES
If wiring the Bodyguard-T to a BEA module (e.g. LO21, MC15), refer to the respective schematic for the module.
Monitoring may not be used if wiring to a BEA module; therefore, the DIP switch must be switched off.
Once wired, feed the free end of the cable through the wire passage hole (page 3, step 8), and into the header.
Pull the cable completely through and route it to the location of the automatic door control.
Refer to the respective User's Guide for the BEA product with which you are interfacing.
Ensure a dedicated power source of 12 or 24 VAC / VDC ±10% (1024VAC may be used for powering this product).
MONITORING DIP SWITCH POSITION
The monitoring DIP switch is in the ON position by default. This must be placed in the OFF position if the
door control does not support monitoring.
Monitoring OFF = switch positioned to the right
Monitoring ON = switch positioned to the left
Replace lenses, eye shield, and end caps before proceeding.
75.5905.06 BODYGUARD-T 20190402
Shut off all power going to the header before attempting any wiring procedures.
10-PIN CONNECTOR (hard-wire connections)
Wire Color
BLACK
RED
WHITE
GREEN
WIRING TO NON-MONITORED DOOR CONTROLS
1. Plug the 10-pin connector to the Bodyguard-T
using the provided cable (without terminating the
monitoring wires) OR hard-wire using the 7-pin
terminal.
Also verify that the monitoring DIP switch is set to
OFF.
2. Hard-wire to the door control. Reference the table
below for connection points.
RED
BLACK
WHITE
GREEN
BROWN
BLUE
Position
Connection
6
Normally Closed
7
Monitoring (+)
8
Monitoring (-)
9
Data (+)
10
Data (-)
Wire Color
YELLOW
PURPLE/YELLOW
PURPLE
BLUE
BROWN
Page 5 of 12