Install Kenco Nfs-3 No-Flow Switch; Fi Gu Re 17 Kenco Nfs-3 No-Flow Switch - GE H301 Series Operating Manual

High speed reciprocating compressors
Table of Contents

Advertisement

An example of an electronic no flow device (ENFD) is DNFT
Examples of mechanical no flow devices (MNFD) that are used are Kenco
Lincoln
.
®
www.kenco-eng.com

install Kenco NFS-3 No-Flow Switch

Kenco NFS-3 No-Flow Switch
FiguRe 17
Switch MUST be mounted either vertically (terminal end up)
or at a minimum angle of 20 º off horizontal with terminal
end at the high point. This prevents water from accumulating
1.
A 25 micron sintered bronze or similar in-line type filter should be installed
ahead of the No- Flow switch. These are available from either KENCO or most
manufacturers of lubricators.
2.
o assure constant oil viscosity, mount switch in a warm place near cylinder
www.noflo.com
www.graco.com
around switch contact.
Complies with ANSI Z535, ISO 3864, OSHA 1910.145 (f) (9)
.
®
and
®
H301/302 HSR Compressors | Rev. 2.2 | 83