Installation Of Indoor Unit; Handling Of Outdoor Unit; Power Requirements - Gree SEER13 Series Technical & Service Manual

Household unit
Table of Contents

Advertisement

Household Unit Technical Service Manual

1.4.2.2 Installation of Indoor Unit

For HNF series U.S household unit, three installations are available at your option:
Upward Blow Installation

1.4.3 Handling of Outdoor Unit

To handle the unit, be sure to use two ropes of enough length to lift from four directions. To avoid deviation
from the center of unit, the angle between the lifting ropes must be less than 40

1.4.4 Power Requirements

The power capacity shall be enough high and the section area of the cable shall be enough big. For
detail, please consult your dealer or professional engineer.
The air conditioning unit must be securely earthed. The earth wire shall be connected to the special
earthing device of the construction. Never connect the earth wire to the gas pipe, water pipe, lightning
arrestor or telephone earth wire.
The circuit must be installed by professional technicians in accordance with the national cabling rules.
In the fixed circuit, leakage protection switch and air switch of enough power capacity must be installed.
Level Blow Installation
40¡ ã
Below 40℃
9
Downward Blow Installation
o
. Please refer to below:
危险
DANGER

Hide quick links: