Household Unit Technical Service Manual
Operating Procedures
2) Remove the axial flow fan
Remove the cover plate (Fig. 4) and put it aside.
Remove the screws fixing the axial flow fan.
Pull the axial flow fan upward to remove
it from the motor axis.
3) Remove the motor
Remove the 4 nuts fixing the motor.
Pull the cover plate upward and remove the motor (Fig. 5)
4) Remove the side plate
Loosen the tapping screws fixing the side plate.
Pull outward to remove the side plate (Fig. 6).
Screw
Tapping
screw
37
Illustration
Fig. 4
图 5