Important Safety Information
Important Safety Information
If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, per-
sonal injury or death.
BEFORE LIGHTING: Smell all around the working area
for gas. Be sure to smell next to the ground because
propane is heavier than air and will settle on the ground.
DAILY: Check for gas leaks. Use mild soap and water
solution or other approved method. Apply solution to all
gas lines and fittings then watch for gas bubbles.
NOTE: Burners will need to be ignited to test gas lines
and fittings downstream of gas safety valves (CC and
HH). Ignite burners only after thoroughly checking gas
line and fitting upstream of gas safety valves.
8
WHAT TO DO IF YOU SMELL GAS OR FIND GAS
BUBBLES:
• Evacuate all unqualified personnel from area
• Do not try to light any burner
• Do not strike a flame
• Do not use electric fans to remove gas from area
• Do not touch any electric switch and do not use
any phone
• If leak is from a gas fitting, tighten fitting until leak
stops
• If leak is from a gas line, shut off at LP-gas cylin-
der and replace gas line
• Immediately call your gas supplier from a remote
phone. Follow gas supplier's instructions.
• If leak can not be stopped by shutting off LP-gas
cylinder shut-off valve, immediately call your gas
supplier from a remote phone. Follow gas sup-
plier's instructions.
• If you cannot reach your gas supplier call the fire
department
ti14560a
Use only your hand to push in or turn the kettle gas
safety valve (CC). Never use tools. If the knob will not
push in or turn by hand, do not try to repair it; call a qual-
ified service technician. Attempted repair or force may
result in a fire or explosion.
ti14561a
Do not use this equipment if any part has been under
water. Immediately call a qualified service technician to
inspect equipment and all components. Replace defec-
tive parts only with approved manufactured parts.