Graco 248824 Instructions And Parts
Graco 248824 Instructions And Parts

Graco 248824 Instructions And Parts

Feed and solvent flush kits

Advertisement

Quick Links

Instruction - Parts
Feed and
Solvent Flush Kits
For use with proportioner systems. For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for model information, including
maximum working pressure.
Agitator kit 248824 and
Feed pump kit 248825 shown
Solvent flush kit
248826 shown
310863M
TI5726
TI5675
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 248824 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graco 248824

  • Page 1 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 2 for model information, including maximum working pressure. Agitator kit 248824 and Feed pump kit 248825 shown Solvent flush kit 248826 shown TI5726 TI5675...
  • Page 2: Table Of Contents

    Installation ....... . 6 Graco Information ......16 Operation/Maintenance .
  • Page 3: Manual Conventions

    Manual Conventions Manual Conventions WARNING Hazard Symbol WARNING: a potentially hazardous situation which, if not avoided, could result in death or serious injury. Warnings in the instructions usually include a symbol indicating the hazard. Read the general Warnings section for additional safety information. CAUTION CAUTION: a potentially hazardous situation which, if not avoided, may result in property damage or...
  • Page 4: Warnings

    Do not alter or modify equipment. • For professional use only. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. •...
  • Page 5 Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. •...
  • Page 6: Installation

    Installation Installation ™ If this equipment is used in a Hydra-Cat or Xtreme Install feed kits ™ proportioning package, see manual 310794. Install solvent flush kit See F . 2. Install feed pump (101) in drum and secure with bung adapter (BA).
  • Page 7 Installation Grounding Install agitator kit See F . 3. Install agitator (1) in drum. WARNING Screw air line fitting (2a) into agitator inlet. Connect air line coupler (2b) into Your system must be grounded. Read warnings, page fitting (2a). • Proportioner pump: follow instructions in propor- tioner operation manual.
  • Page 8: Operation/Maintenance

    Operation/Maintenance Operation/Maintenance Troubleshooting/Repair Refer to separate pump and agitator manuals for opera- Refer to separate pump and agitator manuals for opera- tion and maintenance instructions. See parts lists begin- tion and maintenance instructions. See parts lists begin- ning on page 9 for manual numbers. ning on page 9 for manual numbers.
  • Page 9: Parts

    Parts Parts Part No. 248824, Agitator Kit with Air Connection 1//8 npt Ref. Part No. Description Qty. 224854 AGITATOR, helix; see 308175 249002 KIT, air line, agitator 2a 169969 FITTING, air line 2b 208536 COUPLER, air line 2c 203266 HOSE, coupled, air...
  • Page 10 Parts Part No. 248826, Solvent Flush Kit Ref. Ref. Part No. Description Qty. Part No. Description Qty. 104984 TEE, pipe 223596 PUMP, Monark, 23:1 (chrome); see 223541 HOSE, coupled, 50 ft (15.24 m) 307619 100004 SCREW, cap, hex head 15E737 SUPPORT, clamp, solvent pump 100132 WASHER, flat 164259 ELBOW, street 100052 WASHER, lock...
  • Page 11 Parts Part No. 248885, Solvent Pump, 5 Gallon Pail-Mount Ref. Ref. Part No. Description Qty. Part No. Description Qty. 114575 PLUG, button 240435 COVER, pail 114371 KNOB, screw 223596 PUMP, Monark, 23:1 (chrome); see 238909 WIRE, grounding assembly 307619 187190 STRAINER 100644 SCREW, cap, socket head 223756 HOSE, coupled, 15 ft (4.57 m) 100016 WASHER, lock...
  • Page 12 Parts Part No. 248951, Solvent Flush Kit, Merkur Ref. Ref. Part No. Description Qty. Part No. Description Qty. 223541 HOSE, coupled, 50 ft (15.24 m) 233900 SPRAYER, Merkur; see 309463 15E889 NUT, clamp, unistrut mount 15E737 SUPPORT, clamp, solvent pump 100004 SCREW, cap, hex head 100450 SCREW, cap, hex head 100132 WASHER, flat...
  • Page 13 Parts Part No. 258980, Solvent Flush Kit, 45:1 Merkur Ref. Ref. Part No. Description Qty. Part No. Description Qty. 100131 NUT, full hex 262287 PUMP, solvent; see manual 312794 100450 SCREW, cap, hex hd 501a LW050A LOWER, 50cc; see manual 312792 15E889 NUT, clamp, mount, unistrut 501b M12LN0 MOTOR, 1200cc;...
  • Page 14 Parts Part No. 262393, Solvent Flush Kit, 45:1 Part No. 24F126, Air Control Module Merkur Ref. Part No. Description Qty. Ref. 24F125 PANEL, air controls Part No. Description Qty. 15T500 GAUGE, pressure, air, 1/8 262392 PUMP, solvent, 6 in, 50cc; with suction 15T536 REGULATOR, air, 3/8 npt hose;...
  • Page 15 Parts 310863M...
  • Page 16: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.