Planar LookThru LO552 Series User Manual page 13

Display series rs232
Hide thumbs Also See for LookThru LO552 Series:
Table of Contents

Advertisement

Command
Setting
Code
DNS Server 2 NETWORK.DNS2
1213
EDID Timing EDID.TIMING
400
EDID Zone
EDID.SELECTEDC
401
O NNECTOR
Enable
LED.ENABLE
1902
Status LED
Error Log
ERROR.LOG
2311
Factory
RESET
2400
Reset
Firmware
FIRMWARE.UPDA
2200
Update
TE
Planar LookThru Display Series RS232 User Manual
020-1381-00B
Modifiers
=?
0 = STATIC
String
[None = Current
(for reads only]
[None = STATIC
(for writes only]
=?+-!
Mod 1: Input
Signed Integer
0 = OPS
-3 = 4K60
1 = HDMI.1
-2 = 4K30
2 = HDMI.2
-1 = 1080P
3 = HDMI.3
4 = HDMI.4
5 = DP
6 = ALL
Mod 2: Param
0 = UPDATE
1 = HACTIVE
2 = VACTIVE
3 = VREFRESH
4 = FULL.SPEC
5 = PCLK
6 = HBLANK
7 = HFP
8 = HSYNC
9 = VBLANK
10 = VFP
11 = VSYNC
12 = FACTORY
13 = TYPE
=?+-
0 = OPS
1 = HDMI.1
2 = HDMI.2
3 = HDMI.3
4 = HDMI.4
5 = DP
6 = ALL
=?
0 = DISABLE
1 = ENABLE
?
Log Entry
Number
1-65535
!
0 = USER
1 = FACTORY1
=?!
Mod 1: Firmware
String
0 = AUTO
1 = VP.AP
2 = HDMI
Mod 2: Type
0 = START
1 = PACKET
2 = FINISH
3 = URL
Example
Yes
[Read the current DNS server 2 value]
NETWORK.DNS2?
NETWORK.DNS2:"172.16.0.191"
[Write the DNS server 2 for static IP]
NETWORK.DNS2(STATIC)="8.8.4.4"
NETWORK.DNS2(STATIC):"8.8.4.4"
No
[Read the EDID type for HDMI 1]
EDID.TIMING(HDMI.1, TYPE)?
EDID.TIMING(HDMI.1 TYPE):4K60
[Set the HDMI 2 EDID horizontal active to
3840]
EDID.TIMING(HDMI.2, HACTIVE)=3840
EDID.TIMING(HDMI.2 HACTIVE):3840
[Update the HDMI 2 EDID]
EDID.TIMING(HDMI.2, UPDATE)
EDID.TIMING(HDMI.2 UPDATE)@ACK
No
EDID.SELECTEDCONNECTOR=HDMI.1
EDID.SELECTEDCONNECTOR:HDMI.1
Yes
LED.ENABLE=ENABLE
LED.ENABLE:ENABLE
No
ERROR.LOG(1)?
ERROR.LOG(1):"Wed Sep 16 13:39:33
2015 - CRIT- Power supply 2 issue"
No
RESET(USER)
RESET(USER)@ACK
Yes
FIRMWARE.UPDATE
FIRMWARE.UPDATE(AUTO
START)@ACK
RS232 Codes
Notes
Selects a secondary DNS
server
See Main -> Advanced
Settings -> EDID
UPDATE modifier is the only
one that supports the action
operator
See Main -> Advanced
Settings -> EDID -> Selected
Connector
See Main -> Advanced
Settings -> System Settings ->
Enable Status LED
Lists any faults that have
occurred in the system. Entry
#1 is the most recent. An
empty string returned means
that there are no more error
log entries after that entry.
USER is the same as Main ->
Advanced Settings -> System
Settings -> Factory Reset.
FACTORY1 resets everything
that USER resets plus EDID
customizations, network
settings and presets.
See Main -> Advanced
Settings -> System Settings ->
Firmware Update
Page | 13