Use this setting to determine the type of events to be entered in the Diagnostic Log. If set to
Debug, every event will be logged. If set to Error, only error events are logged.
Diagnostic Log Verbosity options: Debug, Info, Warning, Error
Default is Info

7.3.4 EMP-WIU Configuration

EMP-WIU configuration screen (Figure 7-21) allows the encrypted RC2 key to be entered,
message parameters to be set, the WIU source address to be assigned, additional addressing
information, plus port and additional message configuration parameters. All parameter settings
are described in the following paragraphs.
SIG-00-07-11
Version No.: B.2

Figure 7-20 Diagnostic Log Verbosity Levels

VERIFY THAT VIU-20 IS PROGRAMMED AS SPECIFIED BY THE
RAILROAD'S OR AGENCY'S WITH THE CORRECT MCFCRC,
UCN, ATCS SITE IDENTIFICATION NUMBER (SIN). FAILURE TO
DO SO MAY LEAD TO INCORRECT OR UNSAFE INDICATIONS
ON THE VIU-20 UNIT.