VIU WEB BROWSER USER INTERFACE

7.0
VIU WEB BROWSER USER INTERFACE
7.1

INTRODUCTION

The VIU Web browser user interface will run on Windows Explorer (versions 6 & 7) and on
Mozilla Firefox browser (version 2 or higher). The Web browser user interface allows local or
remote configuration of certain VIU non-vital parameters, plus access to the Event and
Diagnostic logs that can be used to isolate VIU system problems (see Section 8 – Maintenance
and Troubleshooting).
7.2

LAUNCHING THE VIU WEB BROWSER

7.2.1 User Computer Setup

Setting up a computer to connect with the VIU-20 follows standard fundamental LAN protocol.
The User Ethernet Port defaults as a DHCP Server. Setting the computer as a DHCP client will
enable the VIU-20 to assign the computer an IP address. The user can also manually set up the
computer's TCP/IP properties (e.g. IP address 192.168.1.105, subnet as 255.255.255.0) to
connect with the VIU-20 as shown in the figure below. The example shown is for Windows XP
and varies between Windows versions (Vista, Windows 7). This procedure is NOT necessary
unless the intent is to set up the laptop Ethernet port to something other than a default
configuration.
.

Figure 7-1 Establishing WEB U/I Setup Parameters

SIG-00-07-11
Version No.: B.2

SECTION 7

Railroad or agency guidelines may require IT support and/or
authorization prior to changing computer settings.
VIU WEB BROWSER USER INTERFACE
NOTE
7-1
SEPTEMBER 2012 (REVISED OCTOBER 2019)