3.2.2.3

Upload Files From USB Drive Into VIU

To upload (Put) the desired file, press ENTER until the desired file is shown, select YES, and
the file will be uploaded into the USB Drive.
Put Vital MCF > VIU? Select File: No Yes
Put Vital CFG > VIU? Select File: No Yes
Put Mstr Exec > VIU? Select File: No Yes
Put Slv Exec > VIU? Select File: No Yes
Put N-V CFG > VIU? Select File: No Yes
Put N-V Exec > VIU? Select File: No Yes
Put RC2 Key > VIU? Select File: No Yes
Put PTC CFG XML > VIU? Select File: No Yes
Example 1: Upload Vital MCF From USB Drive Into VIU
Insert the USB drive containing the Vital MCF into the front panel USB port.
The first item in the USB menu appears on the front panel display.
Using the up () or down () arrow key on the front panel keypad, scroll through the menu
to PUT VITAL MCF > VIU?
Use the left () or right () arrow key to display YES, then press the Enter key.
The operation will pause while the VIU builds the file list.
If the USB drive contains more than one of the file type selected, the right arrow symbol ()
will appear to the right of the file name. Press the right () arrow key to scroll through
the list of available files until the desired file name is displayed.
Press the Enter key.
Following successful upload of the MCF, the menu will advance to the next item.
Scroll to EXIT USB MENU?
Select YES, then press Enter to exit the USB menu.
The procedure for uploading MEFs, configuration files, and the RC2 Key is similar to the one
provided in Example 1.

3.2.3 Exiting the USB Drive

To exit the USB Drive functions, either scroll to Exit USB Menu? No Yes, select Yes and
remove the USB Drive from the front panel or simply remove the USB Drive whenever the USB
Drive LED is green. The unit will automatically reboot the vital side.
SIG-00-07-11
Version No.: B.2
DO NOT REMOVE POWER FROM THE UNIT WHEN THE
MESSAGE "PLEASE WAIT. DO NOT REMOVE POWER FROM
UNIT" APPEARS. IF POWER IS REMOVED BEFORE THE
TRANSFER
IS
COMPLETE,
UNCONFIGURED AND NOT RETURN TO OPERATION.
CAUTION
THE
UNIT
3-5
SEPTEMBER 2012 (REVISED OCTOBER 2019)
BASIC VIU OPERATION
WILL
REMAIN

Advertisement

Table of Contents
loading

This manual is also suitable for:

A80515

Table of Contents