Cleaning The Side Flue Gas Pass; Fans Cleaning; Replacing The Fan - Cadel KOOK 60 4.0 Installation, Use And Maintenance Manual

Wood cooking stove
Table of Contents

Advertisement

EN
Fig. 75 - Remove the screws
• Open the cleaning cap under the oven by undoing the two screws with an 8 mm spanner (see Fig. 75 page
30 and Fig. 76 page 30).
• Turn the valve under the oven by 90° using the poker (see Fig. 77 page 30).
• Scrape and vacuum the combustion residues at the bottom of the stove.
When you have finished cleaning, ALWAYS put the cap back in place!
13.14

CLEANING THE SIDE FLUE GAS PASS

Clean on a yearly basis (and if necessary every month) the inside of the side flue gas pass.
• Clean the side fume passages with the brush provided (see Fig. 78 page 30).
13.15

FANS CLEANING

For models with ventilation, clean every the year the room fan from ash or dust which can cause a blade
unbalance and a greater noise.
As this operation is so delicate it must therefore be executed by an Authorized Technician.
13.16

REPLACING THE FAN

To replace the fan proceed as follows:
• Remove the plug from the socket.
• Remove the side panels (see relative chapter).
• Disconnect the fastons and remove the screws from the faulty fan.
• Replace the fan and repeat the operation in the reverse order.
30
Fig. 76 - Remove the cap
Fig. 78 - Cleaning with brush
KOOK 60 4.0 - KOOK 67 4.0 - KOOK 70 4.0 - KOOK 80 - KOOK 87 - KOOK 90 4.0
Fig. 77 - Turn the valve