8

CHIMNEY FLUE

EN
8.1

INTRODUCTION

This chapter about the Chimney Flue has been drawn up in cooperation with Assocosma (www.assocosma.org)
and is based on European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443 - UNI 10683:2012).
It provides instructions for a good and correct execution of the chimney flue but it does not absolutely replace
the current standards which the qualified manufacturer/installer should comply with.
The company declines any responsibility regarding the bad running of the stove if it is due to the use of a no
correctly dimensioned chimney flue which does not respect current regulations.
8.2
CHIMNEY FLUE
• The chimney flue or chimney is of great importance for the correct running of the heating appliance.
• It is fundamental that the chimney flue is perfectly built and always maintained with a perfect efficiency.
• The chimney flue must be sole with insulated stainless-steel pipes or installed on the existing chimney flue.
• Both this solutions must be endowed with an inspection door.
8.3

TECHNICAL FEATURES

• The chimney flue must be sealed from fumes.
• It must have a vertical run without narrowing. It must be realized with fume and condensation resistant
materials with thermal insulation and able to last against usual mechanical stresses.
• The stove must be spaced out from fuels or flammable materials with an air gap or with insulating materials.
Check the distance with the chimney manufacturer.
• The chimney entrance must be placed in the same room where the appliance is installed or otherwise in
6
Please check with your local authorities if exists any restrictive regulation which regards the
combustible air inlet, the fumes exhaust system, the chimney flue and the chimney pot.
LEGEND
Fig. 2 page 6
1
Height over the ridge of the roof = 0,5 mt
2
Roof inclination ≥10°
3
90°
4
Measured distance at 90° from the roof surface = 1,3 mt
It must be insulated to avoid condensation and to reduce fume cooling effects.
Fig. 1 - Inclined roof