3.4

Technical Data

Digital Laser Measure
Article number
Measuring range (typical)
Measuring accuracy (typical)
Lowest indication unit
Measuring duration
– typical
– maximal
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter (at 25 °C) approx.
– at 10m distance
– at 20m distance
Batteries
Battery service life in measuring opera-
tion, approx.
Weight according to EPTA-Procedure
01:2014
Dimensions
The working range increases depending on how well the laser
A)
light is reflected from the surface of the target (scattered, not
reflective) and with increased brightness of the laser point to
the ambient light intensity (interior spaces, twilight). In unfa-
vourable conditions, e.g., with extreme interior illumination or a
badly reflecting surface, the measuring range may be limited.
In unfavourable conditions, e.g., with extreme interior illumina-
B)
tion, badly reflecting surface or the room temperature deviating
heavily from 25 °C, the maximum deviation can be up to ±7mm
per 15 m. In favourable conditions, a deviation influence of
±0.05 mm/m must be taken into account.
The measuring tool can be clearly identified with the
serial number 5 on the type plate.
Robert Bosch GmbH
Product Description and Specifications | GLM 20 | 15
4.
4.1
GLM 20
3 601 K72 E..
Alkali-manganese batteries are recommended for the
0.15–20 m
A)
measuring tool.
±3.0mm
B)
1mm
To open the battery lid 3, press the latch 4 in the direc-
tion of the arrow and remove the battery lid. Insert the
0.5 s
4 s
batteries. When inserting, pay attention to the correct
– 10 °C ... +40 °C
polarity according to the representation on the inside of
– 20 °C ... +70 °C
the battery compartment.
90 %
2
When the battery symbol
635 nm, <1mW
time on the display, measurements are still possible for
approx. 15 minutes. When the battery symbol flashes,
9mm
18mm
the batteries must be replaced; measurements are no
2 x 1.5 V LR03 (AAA)
longer possible.
5 h
Replace all batteries at the same time. Only use same-
0.13 kg
brand batteries with the identical battery capacity.
100 x 36 x 23 mm
Remove the batteries from the measuring tool
when not using it for extended periods. When stor-
ing for extended periods, the batteries can corrode
and self-discharge.